Refrigerant - In Case Of R410A Or R32 - Daikin RXF50D5V1B Installer's Reference Manual

Hide thumbs Also See for RXF50D5V1B:
Table of Contents

Advertisement

2
|
General safety precautions
770
760
750
740
730
720
710
700
690
680
670
660
650
640
630
620
610
600
590
580
570
560
550
540
530
520
510
500
490
480
470
460
450
440
430
420
410
400
390
380
370
360
350
340
330
320
310
300
290
280
270
260
250
240
230
220
210
200
190
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
2.6 3 3.4 3.8 4.2 4.6 5 5.4 5.8 6.2 6.6 7 7.4 7.8 8.2 8.6 9 9.4
1.8
2.2
2
2.4 2.8 3.2 3.6 4 4.4 4.8 5.2 5.6 6 6.4 6.8 7.2 7.6 8 8.4 8.8 9.2
1.843
2.2.3 Refrigerant — in case of R410A or R32
Installer reference guide
10
m [kg]
m Total refrigerant charge in the system
A
Minimum floor area
min
(a) Ceiling-mounted unit (= Ceiling-mounted unit)
(b) Wall-mounted unit (= Wall-mounted unit)
(c) Floor-standing unit (= Floor-standing unit)
If applicable. See the installation manual or installer reference guide of your
application for more information.
NOTICE
Make sure refrigerant piping installation complies with applicable legislation. In
Europe, EN378 is the applicable standard.
NOTICE
Make sure the field piping and connections are NOT subjected to stress.
WARNING
During tests, NEVER pressurise the product with a pressure higher than the
maximum allowable pressure (as indicated on the nameplate of the unit).
Ceiling-mounted
unit
(a)
m (kg)
A
(m
)
m (kg) A
2
min
≤1.842
≤1.842
1.843
3.64
2.0
3.95
2.2
4.34
2.4
4.74
2.6
5.13
2.8
5.53
3.0
5.92
3.2
6.48
3.4
7.32
3.6
8.20
3.8
9.14
4.0
10.1
4.2
11.2
4.4
12.3
4.6
13.4
4.8
14.6
5.0
15.8
5.2
17.1
5.4
18.5
5.6
19.9
5.8
21.3
6.0
22.8
6.2
24.3
6.4
25.9
6.6
27.6
6.8
29.3
7.0
31.0
7.2
32.8
7.4
34.7
7.6
36.6
7.8
38.5
8
40.5
8.2
42.6
8.4
44.7
8.6
46.8
8.8
49.0
9
51.3
9.2
53.6
9.4
55.9
9.55
9.55
57.7
Wall-mounted
Floor-standing
unit
unit
(b)
(m
)
m (kg) A
2
min
≤1.842
1.843
4.45
1.843
2.0
4.83
2.0
2.2
5.31
2.2
2.4
5.79
2.4
2.6
6.39
2.6
2.8
7.41
2.8
3.0
8.51
3.0
3.2
9.68
3.2
3.4
10.9
3.4
3.6
12.3
3.6
3.8
13.7
3.8
4.0
15.1
4.0
4.2
16.7
4.2
4.4
18.3
4.4
4.6
20.0
4.6
4.8
4.8
21.8
5.0
23.6
5.0
5.2
25.6
5.2
5.4
27.6
5.4
5.6
5.6
29.7
5.8
31.8
5.8
6.0
34.0
6.0
6.2
36.4
6.2
6.4
6.4
38.7
6.6
41.2
6.6
6.8
43.7
6.8
7.0
46.3
7.0
7.2
49.0
7.2
7.4
51.8
7.4
7.6
54.6
7.6
7.8
57.5
7.8
8
60.5
8
8.2
63.6
8.2
8.4
66.7
8.4
8.6
69.9
8.6
8.8
73.2
8.8
9
76.6
9
9.2
80.0
9.2
9.4
83.6
9.4
9.55
86.2
9.55
4P519439-15Q – 2021.10
(c)
(m
)
2
min
28.9
34.0
41.2
49.0
57.5
66.7
76.6
87.2
98.4
110
123
136
150
165
180
196
213
230
248
267
286
306
327
349
371
394
417
441
466
492
518
545
572
601
629
659
689
720
752
776
RXF50~71D5V1B
R32 split series

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rxf60d5v1bRxf71d5v1b

Table of Contents