2
SPECIFICATIONS
This chapter describes the specifications of the MR-EM340GF.
2.1
General Specifications
This section lists the general specifications.
Item
Operating ambient temperature
Storage ambient temperature
Operating ambient humidity
Storage ambient humidity
Operating ambience
*1
Operating altitude
Mounting location
*2
Overvoltage category
*3
Pollution level
*1 Do not use or store the board under pressure higher than the atmospheric pressure of altitude 0 m. Doing so can cause an operation
failure. When using the board under pressure, please contact with our sales representative.
*2 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power
distribution network and the machinery within premises. Category applies to equipment for which electrical power is supplied from
fixed facilities. The surge voltage withstand level for up to the rated voltage of 300 V is 2500 V.
*3 This index indicates the degree to which conductive material is generated in terms of the environment in which the equipment is used.
Pollution level 2 is when only non-conductive pollution occurs. A temporary conductivity caused by condensing must be expected
occasionally.
2 SPECIFICATIONS
18
2.1 General Specifications
Specification
0 to +55 (32 to 131)
-25 to +75 (-13 to 167°F)
5 to 95% RH: non-condensing
5 to 95% RH: non-condensing
Indoors (where not subject to direct sunlight), no corrosive gas, no significant amount of dirt or dust
2000 m (6561.68 ft.) or less
Inside control panel
or less
2 or less