6 Creating the Program

6.3.2. Writing Outputs

OMRON ELECTRONICS, S.A.
Press "OK (1)" again to enter another
N.A. contact in series with the previous
contact.
Press "ALT (7)" to select the N.C. input.
Use the "♣ ♣ ♣ ♣ (4)" key to move the cursor
and press "
address to 1.
Press "OK (1)" to enter another new
N.A. contact in series with the previous
contacts. This creates the automatic
connection
contacts entered.
First, before entering the output relay, the union line has to be inserted as
follows:
Press "ALT (7)" to enable entering the
connection line option.
The connection line is definitively set up
with the "♣ ♣ ♣ ♣ (4)" key.
Once the line has been inserted, the cursor is situated on the right of the
program line and the output relay is entered:
Press "OK (1)" to enter an initial Q0
output. The output type can be selected
using the "
Press "OK (1)" twice to confirm writing
Q0 output. The cursor will automatically
go to the next line of the program.
ZEN Programmable Logic Module
⇑ ⇑ ⇑ ⇑
(5)" to change the bit
between
the
first
⇑ ⇑ ⇑ ⇑
⇓ ⇓ ⇓ ⇓
(5)" and "
(2)" keys.