Troubleshooting - Dometic HIPRO EVOLUTION Operating Manual

Minibar
Hide thumbs Also See for HIPRO EVOLUTION:
Table of Contents

Advertisement

Available languages

Available languages

HiPro
9

Troubleshooting

Fault
Not cooling
Not cooling, indicator
LED continuously flash-
ing
EN
Possible cause
Power plug not plugged in
No voltage at socket
Electronics or sensors defective
For versions with absorber
cooling: Heating cartridge defective
Auto-defrost active (see chapter
"Defrosting" on page 15)
Minibar recently switched on
Cooling unit defective
Minibar is in silent mode.
Cooling unit blocked
Cooling unit not water-tight
Heating element defective
Error during self-test
Troubleshooting
Solution
➤ Insert power plug into
socket
➤ Check circuit breaker
➤ Contact service
agent.
➤ Service agent: Install
new electronics or
sensor
➤ Contact service
agent.
➤ Service agent: Install
new heating cartridge
No action required
➤ Check cooling again
after 5 to 6 hours
➤ Contact service
agent.
➤ Service agent:
Replace minibar
No action required
➤ Contact service agent
17