Siemens SIMATIC RF170C Operating Instructions Manual page 46

Table of Contents

Advertisement

Diagnostics and error messages
7.2 LED displays on the RF170C communication module
Status and error LEDs on the RF170C connection module
Table 7- 1
ACT_1, ACT_2
ERR_1, ERR_2
PRE_1, PRE_2
RxD_1, RxD_2
The meaning of the individual flashing pattern is described in the relevant FB documentation.
1)
There, you will also find the relevant error descriptions.
In the case of multitag operation, this LED uses a flashing interval to indicate the number of data
2)
carriers currently within the range of the reader.
After start-up or updating the firmware, the LEDs SF, PRE, ERR and ACT indicate the operating
status or errorss of the RF170C:
Table 7- 2
Operating states
SF
PRE_1
ERR_1
Off
Off
Off
On
Off
On
On
Off
Off
On
On
On
On
Off
On
On
On
On
On
Off
On
On
On
Off
On
Off
On
Off
1 x flash
every 3 s
n x flash
every 3 s
Flashing
– = not relevant
* If this fault recurs, the module is defective and must be replaced.
46
Status and error LEDs for RF170C
LED
SF
Group error
The corresponding reader is active processing a user command. (MOBY only)
A flashing pattern indicates the last error to occur.
1)
Indicates the presence of a transponder.
2)
Indicates live communication between the CM and the reader. May also indicate
malfunctions on the reader.
ACT_1
PRE_2
On
Off
Off
Off
Off
Off
On
On
On
Off
On
Off
On
On
On
On
On
On
Off
Off
Rapid
flashing
Meaning
ERR_2
ACT_2
Description
Off
Off
Startup active
Off
Off
Checksum error at startup *
On
Off
Firmware invalid *
On
On
LED test for approximately 4 seconds;
otherwise firmware error *
On
On
Checksum error at startup *
On
On
Checksum error of the firmware *
On
On
External RAM defective *
On
On
ESSA3 defective *
Off
On
ID error firmware *
1 x flash
Off
RF170C successfully started up, waiting for
every 3 s
reset command
m x flash
The last reported error in the channel can
every 3 s
be seen from the number of flashes (n, m).
Flashing
Rapid
Firmware update; alternate flashing of the
flashing
error LEDs at approximately 1 Hz
Operating Instructions, 02/2022, J31069-D0176-U001-A6-7618
SIMATIC RF170C

Advertisement

Table of Contents
loading

This manual is also suitable for:

6gt2002-0hd016gt2002-1hd01

Table of Contents