Parameter settings
5.5 Parameters and commands of the Ident profile
Command table of the Ident profile
The following table contains all the commands supported by the Ident profile and the
"AdvancedCMD" block.
Table 5- 4
Commands of the Ident profile
Command
Command code
HEX
PHYSICAL-READ
70
PHYSICAL-WRITE
71
READER-STATUS
74
TAG-STATUS
73
INVENTORY
69
FORMAT
66
PUT
65
WRITE-ID
67
KILL-TAG
6A
LOCK-TAG-BANK
79
EDIT-BLACKLIST
7A
GET-BLACKLIST
6C
READ-CONFIG
61
WRITE-CONFIG
78
You will find detailed information on parameters of the Ident profle in the manual "Ident
Profile and Ident Blocks" in the section "Commands of the Ident profile".
38
Parameters used
ASCII
'p'
OFFSETBUFFER, EPCID_UID,
LEN_ID, LEN_DATA,
ADR_TAG, MEM_BANK,
PSWD
'q'
OFFSETBUFFER, EPCID_UID,
LEN_ID, LEN_DATA,
ADR_TAG, MEM_BANK,
PSWD
't'
OFFSETBUFFER, ATTRIBUTES Reads out the status of the reader.
's'
OFFSETBUFFER, EPCID_UID,
LEN_ID, ATTRIBUTES
'i'
OFFSETBUFFER,
ATTRIBUTES, DURATION,
DUR_UNIT
'f'
OFFSETBUFFER, EPCID_UID,
LEN_ID, LEN_DATA
'e'
OFFSETBUFFER, EPCID_UID,
LEN_ID, LEN_DATA
'g'
OFFSETBUFFER, EPCID_UID,
LEN_ID, NEW-LEN_ID, PSWD
'j'
EPCID_UID, LEN_ID, PSWD
'y'
EPCID_UID, LEN_ID, PSWD,
ACTION, MASK
'z'
EPCID_UID, LEN_ID, MODE
'l'
OFFSETBUFFER
'a'
--
'x'
LEN_DATA, CONFIG
Description
Reads data from a transponder / optical reader
system by specifying the physical start address, the
length and the password.
Writes data to a transponder by specifying the
physical start address, the length and the
password.
Reads out the status of a transponder.
Requests a list of all currently accessible
transponders within the antenna range.
Initializes the transponder.
Transfers further commands not specified in the
standard profile. To this end, a corresponding data
structure is defined in the send data buffer for
each command.
RF680R/RF685R:
Writes a new EPC-ID to the transponder.
RF680R/RF685R:
The transponder is permanently deactivated.
RF680R/RF685R:
The corresponding memory area of the
transponder is blocked as specified.
RF680R/RF685R:
The black list is processed. The current transponder
can be added, all identified transponders added,
individual transponders deleted or all transponders
deleted.
RF680R/RF685R:
The entire TagIDs are read out from the black list.
Reads out the parameters from the
communications module/reader.
Sends new parameters to the communications
module or reader.
Operating Instructions, 02/2022, J31069-D0176-U001-A6-7618