Electrical - Konica Minolta Magicolor 2300 DL User Manual

Konica minolta magicolor 2300 dl: users guide
Hide thumbs Also See for Magicolor 2300 DL:
Table of Contents

Advertisement

RAM
Optional RAM

Electrical

Voltage and Power
Voltage and
frequency
Phase
Power
consumption
Certification
Current
Mode
Operation (100 V)
Operation (120 V)
Operation (220–240 V)
Rush Current
154
Type: PC-100- or PC-133-Compliant SDRAM DIMMs
Base system RAM: 32 MB
Total RAM: Upgradable to 288 MB
128 and 256 MB DIMMs
For information about DIMMs recommended for
your printer, see the magicolor 2300 DL Answer
Base through the Internet at
printer.konicaminolta.net/support, or contact
Technical Support. See the Service & Support
Guide for a list of sources of service and support in
the Americas. The most up-to-date worldwide
information can be found at www.konicaminolta.net/
printer/.
Japan: 100 volts ±10% at 50/60 Hz ±3 Hz
US: 120 volts ±10% at 50/60 Hz ±3 Hz
International: 220–240 volts +10/-15% at 50 Hz ±3 Hz
Single
Mode
Black monochrome
printing
Color printing
Standby
Power saver
ENERGY STAR compliant
Engine and Controller Specifications
Average
Maximum
600 W or less
1100 W or
less
450 W or less
250 W or less
30 W or less
Average
13.0 A or less
11.0 A or less
7.0 A or less
50 A or less (0-Peak)