1631, Issue 4, October 2009
Login
B. Provisioning
Feature
A. DS1 Provisioning
Name
Framing Format
Line Coding
Line Build-Out
DS1 Loopback
DS1 Loopback Timeout
Response to DS1 Loss of
Signal
B. OC3 Provisioning
Response to OC3 Loss of
Signal
C. Unit Provisioning
Unit Type
If necessary, press the ENTER key to view the Login screen. The system asks for a user
name and password for authentication. Follow the steps in Procedure 6.
STEP
1
At the 'User Name:' prompt, type root. Then hit the ENTER key.
2
At the 'Password:' prompt, type root. Then hit the ENTER key.
User Name and Password are preset. Both responses are case-sensitive;
use lower-case letters only.
Root (admin access) can view and modify all values. After passing authentication, users
login to the Main Menu.
Provisioning is performed via the Configuration Manager sub-menu. Table 8 shows
provisionable features and factory-set default settings.
Table 8. O3-4D1L3 Provisioning
Permits assigning a 12-character name to each DS1
Superframe, extended superframe, or unframed
Alternate mark inversion or bipolar with 8-zero substitution
0–133 ft., 133–266 ft., 266–399 ft., 399–532 ft., 532–655 ft., OR
0, 7.5, or 15 dB
Enable or disable
1, 2, 4, 8, 24 minutes, or none (no timeout on manual loopback)
Send AIS to network (fiber), initiate loopback, or no action
Send AIS to DS1.
Turn off DS1 transmitter.
NT (customer-premises equipment) or LT (central office) side of
network
Procedure 6. Logging In
ACTION
NOTE
Option
18
Default
DS1 #
(1, 2, 3, 4)
ESF
B8ZS
0 to 133 feet
Disable
24 minutes
Send AIS to
network
Send AIS to
DS1
LT