Verifying Repairs - Detroit Diesel MBE 900 Technician Manual

Hide thumbs Also See for MBE 900:
Table of Contents

Advertisement

CODES
4.3.2.6

Verifying Repairs

Perform the following steps to verify repairs.
1. Turn ignition OFF.
2. Reconnect all connectors.
3. Turn ignition ON.
4. Start and run the engine for one minute.
5. Stop engine.
6. Check active codes.
[a] If no codes are displayed, troubleshooting is complete.
[b] If a fault code other than SID 146 is logged, refer to Detroit Diesel MBE Electronic
Controls Troubleshooting Guide, 6SE422.
[c] If a fault code in SID 146 is logged, refer to:
Section 4.3.2.1 for code s 146/0
Section 4.3.2.2 for code s 146/1
Section 4.3.2.3 for code s 146/2
Section 4.3.2.4 for code s 146/7
Section 4.3.2.5 for code s 146/12
4-20
All information subject to change without notice. (Rev. 5/05)
7SE940 0505 Copyright © 2005 DETROIT DIESEL CORPORATION