Figure 2-4: GPS Antenna Connections

Cable
STEP 1
STEP 2
STEP 3
STEP 4
GDL 90 Capstone Upgrade Instructions
Shield 0.250
Insulation
Solder Outer Shield
to Connector

Figure 2-5: Right-Angle Coax Connector Assembly

560-1057-00 Rev A
1.000
0.125
-Slide shrink tube over cable.
-Strip cable as shown.
Shrink
Tube
.125
-Flare Outer Shield as Shown
Cap
Matching Ring
-Place cable in connector as shown placing inner
shield inside connector.
Solder Center
-Flatten outer shield against connector.
Conductor
-Solder outer shield to connector.
-Solder center conductor
-Slide matching ring into connector and around
conductor.
-Attach cap.
Solder Cap
2 Places
-Solder cap into place, 2 Places.
-Shrink tube as shown.