Outputs And Sirens - GE Concord 4 Installation Manual

Hide thumbs Also See for Concord 4:
Table of Contents

Advertisement

Chapter 4: Testing and troubleshooting
Codes
555
888
999
Table 16 below describes pager sensor/zone number and user number report codes.
Table 16: Pager sensor/zone code and numbers
Code
000
001–096
600–829
830-837
838-845
846
847
848
850
851
852

Outputs and sirens

You should test all outputs (onboard and SnapCard) to verify configuration
programming.
Note:
Be sure to contact the central monitoring station before activating outputs that
trigger from an alarm condition.
To test outputs:
1. Contact the central monitoring station to inform them you are testing the system.
2. Verify that all wiring at the panel and output devices is correct.
3. Activate the appropriate device to trigger each output as programmed.
4. Verify that each output responds according to the programmed configuration
number. For outputs that trigger sirens, verify that the correct alarm sounds are
produced from these sirens (see Table 17 on page 97).
96
System event
Phone/sensor test
System trouble condition
System in alarm
Sensor/zone or user number
System event not caused by a zone or user
Sensor/zone numbers 1 to 96
Regular user codes 0 to 229 used
Partition master code used
Partition duress code used
System master code used
Installer code used
Dealer code used
Quick arm used
Keyswitch sensor used
System armed Itself (during service or power-up)
Concord 4 Installation Manual