Remove The Front Bezel To Access Front Panel Hard Drives; Drive Fault Led - Dell PowerProtect DD6900 Manual

Table of Contents

Advertisement

Figure 2. Drive fault LED
2. Run the alerts show current command to identify the location of the failed disk. Record the slot number of the failed
disk.
CAUTION:
The physical labeling of the disks on the system chassis, and the disk numbering in do not match.
The physical labeling starts with Disk 0, and starts with Disk 1.
NOTE:
The sample output below only includes the alert object and alert message. It does not include the columns for
the alert ID, post time, severity, and alert class which are part of the actual output.
# alerts show current
sysadmin@localhost# alerts show current
Object
---------------------------
-------------------------------------------------------------------------
Enclosure=1:Disk=4:Cause=NA
to be replaced.
---------------------------
-------------------------------------------------------------------------
There are 1 active alerts.
3. Match the slot number of the failed disk from the alerts show current output to the physical location of the disk.
4. Run the disk beacon command on the failed disk to illuminate the LED.
# disk beacon 1.4
Remove the front bezel to access front panel hard
drives
Steps
1. Unlock the bezel by using the bezel key.
2. Press the release button, and pull the left end of the bezel.
3. Unhook the right end, and remove the bezel.
18
Replace an Operating System Disk
Message
EVT-STORAGE-00031: Disk has a hardware fault and may need

Advertisement

Table of Contents
loading

Table of Contents