Verify The Operation Of A Replacement Power Supply; Return A Faulted Part; Replace A Dc Power Supply - Dell EMC PowerStore 500T Installation And Service Manual

Hide thumbs Also See for EMC PowerStore 500T:
Table of Contents

Advertisement

Figure 42. Inserting the power cable

Verify the operation of a replacement power supply

Steps
1. From PowerStore Manager, select Hardware.
2. Select the appliance where you replaced the power supply.
3. On the Components card, under Rear View, expand BaseEnclosure.
4. Expand the node that includes the power supply, and then select PSU0.
The status of the replacement power supply should read Healthy. If the status is still Faulted, wait a few minutes and
refresh PowerStore Manager. If the status does not change, ensure that the power supply is correctly seated, or contact
your service provider.

Return a faulted part

About this task
For US customers, return defective material within five business days. For International customers, return defective material
within 10 business days. The materials required to return your defective part are supplied with the good part shipment.
Steps
1. Package the faulted part in the shipping box that contained the replacement part.
2. Ship the failed part to your service provider as described in the instructions that were included with the replacement part.
3. For more information about returning customer-replaceable parts:
a. Open PowerStore Manager.
b. Click Settings on the upper right of the screen.
c. Click General Support.
d. Under Drives, Power Supplies, and Other Parts, click Return Part.
e. If your screen does not show the Return Part link, contact your service provider for instructions.

Replace a DC power supply

Take the following actions to remove the faulted power supply and install the replacement power supply into the system.
Base enclosure service procedures
45

Hide quick links:

Advertisement

Table of Contents