Replace a data interface board in an NVMe expansion
enclosure
Take the following actions to remove a faulted data interface board (DIB) from an NVMe expansion enclosure and install a
replacement DIB.
Identify a faulted DIB from PowerStore Manager
Before you replace a DIB, ensure that you have identified its location within the system. Using PowerStore Manager, you can
identify and locate a faulted DIB.
Steps
1. From PowerStore Manager, select Hardware.
2. Select the appliance that contains the DIB that you need to replace.
3. On the Components card, under Rear View, expand ExpansionEnclosure.
4. Select the relevant DIB.
Faulted parts appear in red in the image of the system, and report a status of Faulted in the State field.
Removing a DIB
Steps
1. Remove the Access Module as described in
2. Press down on both orange buttons to release the DIB latches.
Figure 123. Releasing the DIB
Remove an Access Module
NVMe expansion enclosure service procedures
on page 104.
107