Marantz SR6009/U1B Service Manual page 60

Av surround receiver
Table of Contents

Advertisement

3.6.4. Clearing the Protection History
There are two ways to clear the protection history.
(1) Start Protection History Display Mode. Press the button "STATUS" to display the protection history. Press and hold the
button "DIMMER" for 3 seconds.
L1
P R O T E C T
FLD
L2
H I S T O R Y
L3
: D C
FLD
L3
C L E A R
FLD
L3
: N O
(2) Initialize this unit. ( "See "Initializing This
Use the method in 3.6.3.(1) if you do not want to erase your settings from this unit.
b
Warning Displays by POWER LED
If the power is turned off while a protection is detected, the POWER LED (red) flashes in the following ways as a warning
according to the protection status.
(1) ASO/DC protection: Flashes in 0.5-second cycles (0.25 seconds lit, 0.25 seconds unlit)
(2) THERMAL (A/B/E/F) protection: Flashes in 2-second cycles (1 second lit, 1 second unlit)
(3) CURRENT protection: Flashes in 4-second cycles(2 second lit, 2 second unlit)
3.7. 232C Standby Clear Mode
3.7.1. Actions
232C Standby Clear Mode :
Switches from 232C standby mode to normal standby mode.
Starting up
Press the "STATUS" button during the following display to switch to normal standby mode.
L1
3 R S 2 3 2 C
FLD
L2
R E S E T
L3
Press and hold the button "DIMMER" for 3 seconds.
The above is displayed and the protection history is cleared.
Unit"10 page
)
60