Software Verification - Nvidia Jetson AGX Orin Series Compliance Manual

Table of Contents

Advertisement

USB_CALIB[16:11] USB pad HS_CURR_LEVEL[5:0] for Port 1
USB_CALIB[22:17] USB pad HS_CURR_LEVEL[5:0] for Port 2
USB_CALIB[28:23] USB pad HS_CURR_LEVEL[5:0] for Port 3
Calculate the offset from fused HS_CURR_LEVEL value and desired value from Step 1.
3.
For example, if default value is 0x20 and desired value is 0x1C, then offset = -4
a).
For example, if default value is 0x10 and desired value is 0x14, then offset = +4
b).
Note: Maximum allowable offset: ±6 steps.
Provide the "tuned offset value" to software team so they can add the offset value when
4.
initializing the registers in Table 2.

Software Verification

NVIDIA strongly recommends a functional check. Connect the DUT to USB hosts and devices
to perform a functional check.
To check if software has implemented the tuned offset correctly, load new software with offset
included into another DUT and make sure that:
HS_CURR_LEVEL = USB_CALIB fuse + tuned offset steps.
PRELIMINARY INFORMATION
Jetson AGX Orin Series Tuning and Compliance Guide
USB 2.0 Tuning Guide
DA-11040-001_v0.7 | 6

Advertisement

Table of Contents
loading

Table of Contents