System Options
Shelf Alarm Relay Setting STANDARD
ADC Telecommunications, Inc.
Value
Alarm relay terminations on the shelf
backplane support the following alarms:
System ID
Critical - Visual
Critical - Audible
Major - Visual
Major - Audible
Minor - Visual
Minor - Audible
TELEMETRY
Alarm relay terminations on the shelf
backplane support the following alarms:
Shelf ID
System - Major
System - Minor
Major - Visual
Major - Audible
Minor - Visual
Minor - Audible
ENVIRONMENTAL
Alarm relay terminations on the shelf
backplane support the following alarms:
System ID
Critical - Visual
Major - Visual
Minor - Visual
Environmental #1
Environmental #2
Environmental #3
Description
SCP-AMU912-010-06H
Default
STANDARD
(This setting is
automatically set to
ENVIRONMENTAL
when the AMU-912
is plugged into a
field shelf and the
automatic field shelf
provisioning option
is set to ENABLED.)
71