ADC ADCP-90-216 User Manual

Adc 7-inch fiber distribution system splice module model adcp-90-216 user manual

Advertisement

Quick Links

Content
INTRODUCTION ........................................................................... 1
Revision History ....................................................................... 1
List of Changes ....................................................................... 2
Trademark Information .................................................................. 2
Related Publications ................................................................... 2
Admonishments ....................................................................... 2
1. GENERAL ............................................................................ 3
2. FIBER DISTRIBUTION SYSTEM SPLICE MODULE ............................................. 3
3. FDS ACCESSORIES .................................................................... 3
4. DESCRIPTION......................................................................... 5
Chassis .......................................................................... 6
Front and Rear Covers .............................................................. 6
Splice Drawers ..................................................................... 7
5. INSTALLATION ........................................................................ 7
Unpack ........................................................................... 7
Chassis Installation ................................................................. 7
Cable Routing ..................................................................... 9
Fiber Storage ..................................................................... 12
Pigtails .......................................................................... 12
6. SPLICING ........................................................................... 13
7. SYSTEM INTEGRATION SERVICES ....................................................... 14
8. CUSTOMER SUPPORT SERVICES ........................................................ 15

INTRODUCTION

This manual describes the ADC 7-Inch Fiber Distribution System (FDS) Splice Module. The
Splice Module provides splicing and storage capabilities for the 7-Inch FDS. It contains physical
and functional descriptions, installation, and operation information, and is intended for persons
involved in installing and maintaining the fiber distribution system. The user of this manual must
have a basic understanding of fiber optic terminology and concepts.

Revision History

ISSUE
DATE
Issue 1
02/94
Issue 2
01/98
1017825
REASON FOR CHANGE
Original
Update to reflect product changes and reformat to current standards.
7-Inch Fiber Distribution
System Splice Module

User Manual

© 1998, ADC Telecommunications, Inc.
ADCP-90-216
Issue 2, January 1998
Page
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for ADC ADCP-90-216

  • Page 1: Table Of Contents

    8. CUSTOMER SUPPORT SERVICES ... 15 INTRODUCTION This manual describes the ADC 7-Inch Fiber Distribution System (FDS) Splice Module. The Splice Module provides splicing and storage capabilities for the 7-Inch FDS. It contains physical and functional descriptions, installation, and operation information, and is intended for persons involved in installing and maintaining the fiber distribution system.
  • Page 2: List Of Changes

    Related Publications Listed below are related manuals and their publication numbers. Copies of these publications can be ordered by contacting the ADC Technical Assistance Center at 1-800-366-3891 (in U.S.A. or Canada) or 612-946-3000, extension 3475 (outside U.S.A. and Canada). Title...
  • Page 3: General

    Optional vertical cable guides can be attached at each side of the chassis (see 3.02 unless the splice module is installed in an ADC equipment frame which includes guides. The cable guides form a vertical pathway and provide protection and organization for patch cords.
  • Page 4 MODULE = TERMINATION = SPLICE 2- OR 4-INCH (7-FINGERS) (7 FINGERS) 7 FANNING FINGERS Figure 2. Optional Vertical Cable Guides Page 4 1998, ADC Telecommunications, Inc. INTERBAY CABLE MANAGEMENT PANEL 4117-A Figure 1. 7-Inch FDS 4-INCH 2-INCH (RETROFIT) 7 FANNING...
  • Page 5: Description

    Figure 3. 7-Inch FDS Splice Module Components and Dimensions Issue 2, January 1998 Figure 3 and are described in the following Table PIGTAIL CABLE ACCESS OSP/IFC CABLE ACCESS 11.0 IN. 1998, ADC Telecommunications, Inc. ADCP-90-216 7.0 IN. 4118-A Page 5...
  • Page 6: Chassis

    The metal rear cover is hinged at the bottom and is removable. The removable cover provides access to the interior of the chassis for fiber activity. Page 6 1998, ADC Telecommunications, Inc. SPECIFICATION 7 in. (17.78 cm) 17 in.
  • Page 7: Splice Drawers

    The splice module contains up to six splice drawers. Each splice drawer can handle two ADC splice trays. Each ADC splice tray can handle 12 Fusion, heat shrink, mechanical (elastomeric), rotary, FibrLok, Qpak, AOFR clip, or Raychem splices using the appropriate splice chips.
  • Page 8 Install optional vertical cable guides or reinstall the removed guides (see Re-attach the front cover. #12-24 SCREW (2 PLACES - BOTH SIDES) Figure 4. Splice Module Installation in an Equipment Rack Page 8 1998, ADC Telecommunications, Inc. Figure MOUNTING INTERBAY BRACKET MANAGEMENT...
  • Page 9: Cable Routing

    ADCP-90-216 Issue 2, January 1998 VERTICAL CABLE GUIDE MOUNTING HOLES INTERBAY VERTICAL CABLE MANAGEMENT GUIDE MOUNTING PANEL HOLES 1217-A Page 9 1998, ADC Telecommunications, Inc.
  • Page 10 (76.2 cm) of fiber within the splice tray for splicing. If buffer tubes or fiber protector sleeves are needed add them at this time. CABLE CLAMP CABLE SHEATH FIBERS Figure 6. Sheath Opening for OSP/IFC Cables Page 10 1998, ADC Telecommunications, Inc. Figure 6 includes approximately 30 inches 0.75 IN. (1.9 CM) 13 FT. (4.0 M) RECOMMENDED...
  • Page 11 GAP OF NEARLY ZERO TO 0.30 IN. (7.6 MM) WHEN PLACED AROUND CABLE. IF CABLE DIAMETER IS MORE THAN 0.70-IN. (17.8 MM) USE ONLY RUBBER CLAMP. GROMMET CABLE CLAMP PLATE 1998, ADC Telecommunications, Inc. ADCP-90-216 Issue 2, January 1998 IFC/OSP CABLE 1194-A Page 11...
  • Page 12: Fiber Storage

    (either left or right side). OSP CABLE AT LEFT SIDE RADIUS LIMITER FIBERS Figure 8. Fiber Routing in Splice Module Page 12 1998, ADC Telecommunications, Inc. Figure 8, and just onto the splice tray. Coil the fiber bundles RETAINER CLIPS Figure 4132-A...
  • Page 13: Splicing

    BUNDLE FIBER Figure 9. Fiber Routing in Splice Tray Figure 9. The routing in the splice tray is SPLICE SPLICE CHIP FIBERS 3576-B CABLE TIES 1998, ADC Telecommunications, Inc. ADCP-90-216 Issue 2, January 1998 Figure 9. The tie Page 13...
  • Page 14: System Integration Services

    Repeat steps 6.02 through 6.09 for additional splice trays as required. 7. SYSTEM INTEGRATION SERVICES 7.01 ADC offers the following system integration services. For calls originating in the U.S.A. or Canada, dial 1-800-366-3891, extension 3000. For calls originating outside the U.S.A. or Canada, dial 612-946-3000.
  • Page 15: Customer Support Services

    Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages.

Table of Contents