Temperature, Volts, Ohms, Frequency, and Capacitance
To do the temperature, volts, ohms, and capacitance performance tests:
1. Connect the Calibrator NORMAL output and ground to the Product. See Figure 4 for
the connections.
2. Apply the values shown in Table 4. 
If the Product shows indications outside of the limits shown in Table 4, calibration
adjustment is necessary. See "Calibration Adjustment".
325
TRUE RMS CLAMP METER
CAT
600 V
CAT
300 V
Figure 4. Temperature, Volts, Ohms, Frequency, and Capacitance Performance Test Connections