Additional Components; Safety Practices; Electrical Safety Practices - Panduit PAT1M Operation Manual

Automatic cable tie installation system
Hide thumbs Also See for PAT1M:
Table of Contents

Advertisement

ADDITIONAL COMPONENTS

PATMBM Bench Mount
The PAT1M and PAT1.5M Tools can be mounted to the PATMBM Bench Mount to perform hands-free, foot pedal
actuation of the reel-fed PAT1M/PAT1.5M System.
PL283N1 Filter/Regulator
A filter/regulator with a 40 micron maximum element rating must be
used to supply the PDM Dispenser with clean air and to ensure proper
air pressure regulation. The PANDUIT PL283N1 Filter/Regulator
meets the requirements of the PDM Dispenser, and it is
recommended for best results. The PL283N1 includes a 1/4" male
quick connect plug and provides 16 cfm at 85 PSIG (7,5 l/sec. at 5,8
bar).
PDH10-37 Air Supply Hose
The PANDUIT PDH10-37 Air Supply hose is approximately 10 ft. (3
m) long. The hose includes a 3/8 NPT male pipe thread fitting for
attaching the hose to the PL283N1 Filter/Regulator. A 1/4" female quick disconnect fitting is included on the opposite
end of the hose for connection to the dispenser.

SAFETY PRACTICES

The PAT1M/PAT1.5M System is pneumatically and electrically operated and electronically controlled. Therefore,
certain safety practices must be followed.

ELECTRICAL SAFETY PRACTICES

GROUNDING:
In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current which
reduces the risk of electrical shock. This tool is equipped with an electric cord that includes an equipment-grounding
conductor and a grounding plug. The plug must be inserted into a matching outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
DO NOT modify the plug provided. If it will not fit the outlet, have the proper outlet installed by a qualified electrician.
Use only 3-wire extension cords that have 3-prong grounding plugs and 3-pole receptacles that accept the tool's plug.
Replace a damaged or worn cord immediately.
PAT1M/PAT1.5M: PA22222A01_03
Downloaded from
Elcodis.com
electronic components distributor
PAT1M / PAT1.5M OPERATION MANUAL
WARNING
DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE:
DO NOT operate the product in the presence of flammable gases or fumes. Operation of
any electrical equipment in such an environment constitutes a definite safety hazard.