Maintenance; Daily Preventive Maintenance; Extended Maintenance - Panduit PAT1M Operation Manual

Automatic cable tie installation system
Hide thumbs Also See for PAT1M:
Table of Contents

Advertisement

STATUS 3 - Reset EEPROM
STATUS 4 - Reset dispenser RAM
STATUS 5 - Reset tool RAM

MAINTENANCE

DAILY PREVENTIVE MAINTENANCE

The following maintenance of the PAT1M/PAT1.5M System must be performed daily (as needed) to ensure optimum
performance and trouble-free operation of the system.
No more than 180 cycles
No more than 2500 cycles (= ½ cable tie reel)

EXTENDED MAINTENANCE

The following maintenance of the PAT1M/PAT1.5M System must be completed within the recommended intervals to
ensure trouble-free operation and longevity of the system. Certain extended maintenance procedures must be
performed by your maintenance department. Please notify your maintenance department when these specific
maintenance intervals are reached.
PAT1M/PAT1.5M: PA22222A01_03
Downloaded from
Elcodis.com
electronic components distributor
PAT1M / PAT1.5M OPERATION MANUAL
Reset EEPROM
Reset dispenser RAM
Reset tool RAM
INTERVAL
CAUTION: SAFETY GLASSES WITH SIDE SHIELDS MUST BE WORN AT ALL TIMES DURING
THE MAINTENANCE OR ADJUSTMENT OF THE PAT1M / PAT1.5M TOOLS.
CAUTION: ALWAYS DISCONNECT AIR SUPPLY FROM TOOL BEFORE DISASSEMBLY.
CAUTION: ELECTROSTATIC SENSITIVE DEVICE. DO NOT OPEN OR HANDLE EXCEPT AT A
STATIC FREE WORK STATION.
MAINTENANCE PROCEDURE
Empty tool tip collector before full.
(Refer to the Tip Collector section on Page 14.)
Empty dispenser carrier strip scrap bin.
(Refer to the Reloading Procedure section on Page 9.)
Page: 24 of 36
Dec., 2007

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pat1.5m

Table of Contents