Maintenance - Interphase Outlook Operation Manual

Forward scanning sonar
Table of Contents

Advertisement

Maintenance

The Outlook Forward Scanning Sonar has been designed to provide reliable, trouble-free performance
for years. Follow the maintenance tips below to ensure that your Outlook remains problem free.
1) Keep your Outlook clean and dry. Occasionally wipe unit off with a damp cloth, but be careful not to
scratch the lens covering the LCD screen. For stubborn dirt, use a mild soap and a damp cloth. NEVER
USE SOLVENTS SUCH AS PAINT THINNER, ACETONE, OR GASOLINE TO CLEAN YOUR
Outlook.
2) Occasionally clean the face of the depth transducer (sensing surface) and carefully remove any marine
growth. Use a mild detergent, or 220 grit sandpaper, or crocus cloth to remove stubborn growth.
3) If the in-line fuse is blown, replace it with a 2 amp fuse. NEVER REPLACE WITH A HIGHER
AMP RATING ! If the fuse continues to blow, check the polarity of your 12 VDC power source. If the
polarity is correct, check with the Technical Service Department at (408)477-4944.
4) In order to protect your transducer from water damage, paint it with one of the following brands:
Interlux-UltraCoat, Fiberglass Bottom Coat, Super Bottom Coat; Pettit-UniPoxy; Rule-Super KL, Gloss
Dura Poxy. DO NOT use a solvent based paint.
5) DO NOT allow any solvents, i.e. gasoline, acetone, to come in contact with the transducer or
head unit as these may dissolve the material.