Removal Of The Lamp House - Barco HDQ 4K35 User And Installation Manual

Hide thumbs Also See for HDQ 4K35:
Table of Contents

Advertisement

Maintenance
Image 7–4 Refilling the cooling liquid reservoir
Caution:
Nm.
5.
Install the left projector cover. See "Removal of the left cover", page 90.
CAUTION: Never fill the cooling liquid reservoir above the Max level mark.

7.7 Removal of the Lamp House

WARNING: The procedure below may only be performed by "qualified service technicians".
WARNING: Before removing the Lamp House, disconnect the power to the projector mains
terminals and unplug the power cord at the UPS INLET for removal of all power from the projector.
Required tools
10 mm nut driver or flat screwdriver
How to remove the Lamp House from the projector?
1.
Remove the lamp cover.
2.
Release the two retaining screws (1) at the base of the Lamp House. Use a 10 mm nut driver or a flat
screwdriver.
3.
Remove the Lamp House:
1. Grip the Lamp House with the bottom handle (2) and partially slide it out of the Lamp House
compartment.
2. Grip the Lamp House with the top handle also (3) and remove it completely from the projector.
3. Place the Lamp House on a solid and stable support.
Warning:
personal injury.
78
R5905823 /05
HDQ 4K35
Tighten the filler cap sufficiently to avoid cooling liquid leakage. Tighten to a torque of 7
Be aware of the weight of the Lamp House. Take the necessary precautions to avoid

Advertisement