Notes to the Installer

Test Mode
When the heater is connected via a pilot wire system, the test mode allows
the installer to confirm that the heater is responding correctly to the incoming
pilot wire signal.
Pilot wire mode must be enabled in the heater's settings in order for the
appliance to be controlled by a Dimplex controller with pilot wire connection.
Press MENU, BACK and ENTER for ten seconds to enter the service
menu, select Pilot Wire and press ENTER. Select Enable.
The desired comfort temperature should be
selected using
Note: The comfort
temperature can be
changed later if required.
The heater will now enter a test state for four
minutes. During this test state the display screen will
indicate the pilot wire status. Each pilot wire mode
should be verified to ensure correct operation.
Note: Some features are
not available while pilot
wire mode is enabled.
Safety - Overheat protection
For your safety this appliance is fitted with
a thermal cut-out. In the event that the
product overheats for some reason, the cut-
out prevents excessive temperatures on the
product by cutting the power to the heater.
Once the heater has cooled down, it will reset
automatically, it will continue to cycle
6
and . Press ENTER to confirm.
Comms
Standalone
Pilot Wire
RF Module
Select
Comfort SP
21 °C
Test Mode
Pilot Wire
Status
Comfort
Time
remaining
4:00
on and off automatically until the reason for
overheating is removed.
The display screen will flash red to indicate the
product has overheated. To reset the display,
remove the obstruction and hold ENTER for
10 seconds.