Detaching And Attaching The Separation Pad (Retard Roller Cover); When To Replace The Separation Pad (Retard Roller Cover); Detaching And Attaching The Separation Pad - Canon imageFORMULA DR-G1100 Production Document Scanner User Manual

Hide thumbs Also See for imageFORMULA DR-G1100 Production Document Scanner:
Table of Contents

Advertisement

3.

Detaching and attaching the separation pad (retard roller cover)

When replacing the separation pad, perform the following steps to detach it from and attach it to the unit.
When to replace the separation pad (retard
roller cover)
The separation pads are consumables that must be replaced
after feeding about every 6,000,000 pages.
A worn separation pad is no longer able to correctly feed a
document and can cause paper jams. If documents no longer
feed correctly as frequent double-feed, replace the separation
pad.
Detaching and attaching the separation
pad (retard roller cover)
■ Detaching the separation pad (retard roller
cover)
1.
Open the upper unit smoothly.
Upper Unit" on p. 5-3.)
2.
Grasp and pull the retard roller cover with your
fingers to remove it.
(See "Opening the Upper Unit"
on p. 5-3.)
(See "Opening the
5-14
■ Attaching the separation pad (retard roller
cover)
1.
Replace the retard roller cover.
2.
Push the front of the retard roller cover in. Make sure
to hear a latching sound that it is securely returned to
its original position.
3.
Smoothly close the upper unit.
Upper Unit" on p. 5-3.)
CAUTION
Make sure that the hook is completely latched and the retard
roller cover is not loose. If the retard roller cover is loose, the
Document Feed Tray will catch on it causing the scanner to
malfunction.
Chapter 5 Maintenance
(See "Closing the