8. TROUBLESHOOTING

Problem
Power does not
Fuse is blown.
turn on.
(No sound is
produced.)
Incorrect wiring.
No sound output
Power antenna lead is
when operating
shorted to ground or
the unit with
excessive current is required
amplifiers or
for remote-on the amplifiers
power antenna
or power antenna.
attached.
Nothing happens
The microprocessor has
when buttons are
malfunctioned due to noise,
pressed.
etc.
Display is not
accurate.
Sound quality is
Playback head is dirty.
poor.
B NR button 8 is not
pressed.
CD cannot be
Another CD is already
loaded.
loaded.
Sound skips or is
CD is dirty.
noisy.
CD is heavily scratched or
warped.
Sound is bad
Water droplets may form on
directly after
the internal lens when the
power is turned
car is parked in a humid
on.
place.
Cause
Replace with a fuse of the same amperage. If the
fuse blows again, consult your store of purchase.
Consult your store of purchase.
1. Turn the unit off.
2. Remove all wires attached to the power antenna
lead. Check each wire for a possible short to
ground using an ohm meter.
3. Turn the unit back on.
4. Reconnect each amplifier remote wire to the
power antenna lead one by one. If the amplifiers
turn off before all wires are attached, use an
external relay to provide remote-on voltage
(excessive current required).
Press the reset button with a thin rod.
Use a cleaning tape, etc., to clean the head.
When listening to a tape recorded with Dolby NR,
press B NR button 8 and select B NR.
Eject the CD before loading the new one.
Clean the CD with a soft cloth.
Replace with a CD with no scratches or no warped.
Let it dry for about 1 hour with the power on.
Measure
Reset button
ADX5655z
280-7452-00
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pe-2322b

Table of Contents