Control board for lt-286

Advertisement

[Function]
Setting line feed rate of minimum pitch
[Code]
<1B>H<33>H<n>
[Range]
{0 =< n =< FF} Data is described in Hex code.
[Outline]
The line feed rate per line is specified by n/360 inch.
Since an actual mechanical pitch is 1/203 inch, it is internally converted approximate
to the value specified with this command.
[Default]
The initial value is n = 60 (1/6 inch) (18H), being 4.23 mm line feed rate.
[Sample Program]
See Sample Program and Print Results for ESC 2 on Page 43.
[Print Results]
44