Imaging Problems (Both Digital And Analog) - Eizo FlexScan EV2360-WT User Manual

Color lcd monitor
Table of Contents

Advertisement

5-2. Imaging Problems (Both Digital and Analog)

Problem
1. The screen is too bright or too
dark.
2. The brightness changes on its
own.
3. Text is blurred.
4. Afterimages appear.
5. Green / red / blue / white / dark
dots remain on the screen.
6. Interference patterns or pressure
marks remain on the LCD panel.
7. Noise appears on the screen.
8. The positions of windows and
icons are shifted when the
monitor is turned off / on or when
restored from power saving
mode.
9. The color shown on the screen is
not correct.
10. Images are not displayed over the
entire area of the screen.
Possible cause and remedy
• Use "Brightness" or "Contrast" in the Setting menu to adjust it (see
"Color Adjustment" (page
a limited life span. If the screen becomes dark or begins to flicker,
contact your local EIZO representative.)
• If the screen is too bright, try changing the Auto EcoView setting
to "On". The monitor detects the ambient brightness to adjust the
screen brightness automatically (see
• Try changing the Auto EcoView setting to "Off" (see
(page
14)).
• Check whether the PC is configured to meet the resolution and
vertical scan frequency requirements of the monitor (see
Supported Resolutions" (page
• When an image is displayed with a resolution other than
recommended, text or lines in the displayed image may blur. In this
case, try adjusting "Sharpness" in the Setting menu (see
(page
21)).
• Afterimages are particular to LCD monitors. Avoid displaying the
same image for a long time.
• Use the screen saver or power saving function to avoid displaying
the same image for extended periods of time. Depending on the
image, an afterimage may appear even if it was displayed for a short
period of time. To remove such a phenomenon, change the image
or keep the power turned off for several hours.
• This is due to LCD panel characteristics and not a malfunction.
• Leave the monitor with a white or black screen. The symptom may
disappear.
• In the Setting menu, set "Overdrive" to "Off" (see
19)).
• When inputting HDCP system signals, normal images may not be
displayed immediately.
• Turn the setting "On" for "Compatibility Mode" on the "Administrator
Settings" menu (see
"Compatibility Mode" (page
• Try changing "Input Color Format" in the Setting menu (see
Color Format" (page
21)).
• Try changing "Picture Expansion" in the Setting menu (see
Expansion" (page
20)).
17)). (The LCD monitor backlight has
"Auto EcoView" (page
10)).
"Overdrive" (page
26)).
Chapter 5 Troubleshooting
14)).
"Auto EcoView"
"1-3.
"Sharpness"
"Input
"Picture
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flexscan ev2360

Table of Contents