Specification - Canature WaterGroup HT 565BM-75 Owner's Manual

Table of Contents

Advertisement

SPECIFICATION

Flow Rate USGPM
Media
Model
Cu Ft
Service Peak Backwash
HT 565BM-75
0.75
3.0
HT 565BM-100
1.0
3.0
HT 565BM-150
1.5
4.0
HT 565TO-75
0.75
4.0
HT 565TO-100
1.0
4.0
HT 565TO-150
1.5
5.0
HT 565NU-75
0.75
2.0
HT 565NU-100
1.0
3.0
HT 565NU-150
1.5
4.0
Sediment Turbidity Multi-Media Filters
HT 565MM-75
0.75
4.0
HT 565MM-100
1.0
5.0
HT 565MM-150
1.5
7.0
NextSand Turbidity Filters
HT 565NEX-75
0.75
4.0
HT 565NEX-100
1.00
5.0
HT 565NEX-150
1.50
8.0
Water and Time Consumed During Regeneration
Backwash
Minutes
75
10
100
10
150
10
Micron
Mineral
Rating
Tank Size
Iron Filters - Birm
4.0
3.5
8 x 44
5.0
4.0
9 x 48
8.0
5.0
10 x 54 3/4" and 1"
Taste & Odor Filters
5.0
3.5
8 x 44
6.0
4.0
9 x 48
7.0
5.0
10 x 54 3/4" and 1"
Neutralizing Filters
4.0
3.5
8 x 44
6.0
4.0
9 x 48
10.0
5.0
10 x 54 3/4" and 1"
5.0
4.0
15 -20 µ
8 x 44
7.0
5.0
15 -20 µ
9 x 48
10.0
7.0
15 -20 µ 10 x 54 3/4" and 1"
6.0
3.5
3 - 5 µ
8 x 44
8.0
4.0
3 - 5 µ
9 x 48
10.0
5.0
3 - 5 µ
10 x 54
Rapid Rinse
Total Time of
Minutes
Regeneration
Consumed during
Regeneration (GAL)
(Birm, TO, Neu)
10
20
10
20
10
20
Ship
Pipe Size
Weight
Inches
Lbs
Working Temperature = 34-110°F (1-43°C)
(Do not subject the unit to freezing temperatures)
Working Pressure = 30-125 PSIG (137-861 kPa)
3/4" and 1"
67
Voltage = 120V / 60 Hz
Pipe Size = 3/4" and 1"
3/4" and 1"
79
• At the stated service flow rates, the pressure drop
101
through these devices will not exceed 15 psig.
• The manufacturer reserves the right to make
product improvements which may deviate from the
specifications and descriptions stated herein, without
3/4" and 1"
50
obligation to change previously manufactured products
or to note the change.
3/4" and 1"
60
* Do not use water that is microbiologically unsafe
without adequate disinfection before or after the
78
system.
Peak flow rates intended for intermittent use only (10
minutes or less) and are for residential applications only.
3/4" and 1"
93
Do not use peak flow rate for commercial applications
or for a continuous rate when treated water supplies are
3/4" and 1"
120
geothermal heat pump, swimming pool, etc.
164
For satisfactory operation, the pumping rate of the
well system must equal or exceed indicated backwash
flow rate.
3/4" and 1"
79
All units come with plastic bypass
3/4" and 1"
118
144
1/2" - 1"
90
1/2" - 1"
135
1/2" - 1"
175
Total Water
Total Water Consumed
during Regeneration
(GAL) (MM)
70
80
80
100
100
140
Total Water Consumed
during Regeneration (GAL)
(nextSand)
100
140
200
5

Advertisement

Table of Contents
loading