Trouble Shooting Guide / Master Programming Guide - Canature WaterGroup HT 565BM-75 Owner's Manual

Table of Contents

Advertisement

MASTER PROGRAMMING GUIDE
Key Pad Configuration:
MENU
SET/REGEN
Program Valve
1. If screen is locked, press "MENU" for 3 seconds to unlock. Press "MENU"
again to enter level one programming mode and adjust CURRENT TIME.
2. Press "SET/REGEN" to adjust hours. When you have entered the change
value mode, the curser will blink. Press "UP or DOWN" arrows to change
the hour values. Press "SET/REGEN" gain to accept the hour value and
advance to change the minutes value. Press "UP or DOWN" arrows to
change the minute values. Press "SET/REGEN" again to accept the minute
values and advance to adjust the AM/PM values. Press " or "UP or
DOWN" to change the AM/PM value. Press "SET/REGEN" again to accept
the AM/PM value and exit. When you have exited the change value mode,
the curser will stop flashing.
Setting Current Date
1. Press "DOWN" to advance to CURRENT DATE.
2. Press the "SET/REGEN" to change the value. Press "UP or DOWN" to
change the values.
Power the Valve and Configure to Filter
Hold Up and Down Key for 3 Seconds.
Press Set/Regen to Select the Value and Up/
Down Arrow to Change it. Refer to the values on the blocks that
need to be set. Press Down Key to move to the next screen.
SYSTEM LANGAUAGE
ENGLISH
Press DOWN key
VALVE OPERATION
FILTER
Press DOWN key
REGEN MODE
CALENDAR CLOCK
Press DOWN key
REGEN TIME
12:00 AM
Press Menu Key to Exit
Press DOWN key
Setting Vacation Mode
1. Press "DOWN" to advance to VACATION MODE.
2. Press the "SET/REGEN" to change the value. Press "UP or DOWN" arrows to change the values.
Programming Flow Chart
Press SET/REGEN Key and change the values using UP and DOWN Key
CURRENT TIME
12:01 PM
Press DOWN key
CURRENT DATE
JAN/01/2016
Press DOWN key
VACATION MODE
YES NO
SELECT 'NO'
REGEN DAYS
03 DAYS
Press DOWN key
BACKWASH
10 MINUTES
Press DOWN key
RAPID RINSE
10 MINUTES
Press DOWN key
RESTORE DEFAULT
NO
VACATION MODE: This function
may be activated by the user during a
prolonged absence such as vacation.
The system will perform a brief
backwash and rinse based on the
advanced setting. The purpose is to
keep the water fresh in the softener
tank and plumbing system.
35

Advertisement

Table of Contents
loading

Table of Contents