STARTUP INSTRUCTIONS

1. Plug the valve into an approved power source.
2. When power is supplied to the control, the screen will display "WAITING PLEASE" while it
finds the service position.
3. Start an Immediate Manual Regeneration. The valve will immediately start moving to the
BACKWASH position.
4. Open the inlet on the bypass valve slightly and very slowly allow water to enter the unit. (If the
water enters too quickly it will push the carbon up into the control valve and get plugged).
5. Once the unit has filled sufficiently that water is at least equal to the height of the top of the
media shut down the water for 15 – 20 minutes for the carbon to soak. Unplug the power cable.
After the carbon has soaked for the recommended time continue by plugging the power
cable back in.
6. Turn the water back on slowly to backwash until water runs clear to drain.
7. Press any button to advance to the RINSE position. Check the drain line flow. Allow the water to
run for 3-4 minutes or until the water is clear.
8. The valve will automatically advance to the SERVICE position after the RINSE cycle is complete.
Open the outlet valve on the bypass, then open the nearest treated water faucet and allow the
water to run until clear, close the tap and replace the faucet screen.
9. Program time, date, and number of days between regenerations into controller using
Programming Instructions
Note : Carbon filters only:
Once the unit has filled sufficiently that water is at least equal to the height of the media shut
down the water for 15 – 20 minutes for the carbon to soak. After the carbon has soaked for the
recommended time continue with installation instructions.
Program Valve
1. If screen is locked, press "MENU" for 3 seconds to unlock. Press "MENU"
again to enter level one programming mode and adjust CURRENT TIME.
2. Press "SET/REGEN" to adjust hours. When you have entered the change
value mode, the curser will blink. Press "UP or DOWN" arrows to change
the hour values. Press "SET/REGEN" gain to accept the hour value and
advance to change the minutes value. Press "UP or DOWN" arrows to
change the minute values. Press "SET/REGEN" again to accept the minute
values and advance to adjust the AM/PM values. Press " or "UP or
DOWN" to change the AM/PM value. Press "SET/REGEN" again to accept
the AM/PM value and exit. When you have exited the change value mode,
20
the curser will stop flashing.
Setting Current Date
1. Press "DOWN" to advance to CURRENT DATE.
2. Press the "SET/REGEN" to change the value. Press "UP or DOWN" to
change the values.
1. Connect the transformer
to the valve. Plug the
1
12-volt transformer into
a 120 VAC 60 Hz outlet.
Setting Vacation Mode
1. Press "DOWN" to advance to VACATION MODE.
2. Press the "SET/REGEN" to change the value. Press "UP or DOWN" arrows to change the values.
Programming Flow Chart
Press SET/REGEN Key and change the values using UP and DOWN Key
Key Pad Configuration:
MENU
Power the Valve and Configure to Filter
Hold Up and Down Key for 3 Seconds.
Press Set/Regen to Select the Value and Up/
Down Arrow to Change it. Refer to the values on the blocks that
need to be set. Press Down Key to move to the next screen.
SYSTEM LANGAUAGE
Press DOWN key
VALVE OPERATION
Press DOWN key
REGEN MODE
CALENDAR CLOCK
Press DOWN key
Press DOWN key
CURRENT TIME
12:01 PM
Press DOWN key
CURRENT DATE
JAN/01/2016
Press DOWN key
VACATION MODE
YES NO
SELECT 'NO'
SET/REGEN
REGEN DAYS
ENGLISH
03 DAYS
Press DOWN key
BACKWASH
FILTER
10 MINUTES
Press DOWN key
RAPID RINSE
10 MINUTES
Press DOWN key
REGEN TIME
RESTORE DEFAULT
12:00 AM
NO
Press Menu Key to Exit
VACATION MODE: This function
may be activated by the user during a
prolonged absence such as vacation.
The system will perform a brief
backwash and rinse based on the
advanced setting. The purpose is to
keep the water fresh in the softener
tank and plumbing system.