[F6] Utility & MIDI

7 DATA TRANSMIT

Purpose:
Transmits the specified PSR-5700 panel or memory data
via the MIDI OUT connector.
Procedure:
Use the left [-] and [+] buttons to select "Panel" or
"Memory" data (see "Notes" below), then press both the
right [-] and [+] buttons under "-Execute-" on the display
simultaneously to begin data transmission. A bar graph
shows the progress of the transmit operation, and "Com-
pleted!" will appear on the screen when the transmission is
finished.
Notes:
When "Panel" is selected all PSR-5700 panel settings are
transmitted.
When "Memory" is selected the following data types are
transmitted:
LCD
Data Type
Setup
. . . . . . . . . Panel data.
VRegist
. . . . . . Voice registration data.
PRegist . . . . . .
Panel registration data.
SSP
Super style play data.
. . . . . . . . . . .
PadData
. . . . . Multi, tempo, and percussion pad data,
CusVoic
. . . . . Custom voice data.
CusStyl
. . . . . . Custom style data.
Sequent
. . . . Sequencer data.
The selected data is transmitted as a MIDI bulk dump that
can be automatically received by a second PSR-5700 or other
compatible MIDI device.
58
(Remote Control Mode Onlv)
MIDI Bulk Dump Reception
(Memory Data Receive)
The PSR-5700 can receive bulk data transmitted by a sec-
ond PSR-5700 as long as it is not accessing disk data, the
Custom Accompaniment Programmer is not engaged, and the
DOC/General MIDI Level 1 mode is not selected. When a
bulk dump is received the following display will appear:
The bar graph roughly indicates the progress of the bulk
dump receive operation. "Completed!" will appear on the
display when the data has been successfully received.
MIDI Bulk Dump Request
Receiving
Messages
When the REMOTE CONTROL mode is selected and the
PSR-5700 receives a MIDI bulk dump request message from
an external device, The display shown above appears and a
bulk data transmission is performed. Progress of the trans-
mission is shown in bar-graph form on the display.
Bulk Dump Error Messages
If an error is encountered during bulk reception, a
"CHECK SUM DATA ERROR !", "END OF EXCLUS ER-
ROR !", or "HEADER DATA ERROR!" error message will
appear for a few seconds and the receive operation will be
terminated. In the case of a "CHECK SUM DATA ERROR
!" or "END OF EXCLUS ERROR !", the data will be re-
placed up until the point at which the error occurred. Data
being received at the time the error occurred will be initial-
ized. All other data is not affected. In the case of a
"HEADER DATA ERROR!", all data will be left unaltered.
Broken cables and other causes of data errors cause a "BULK
ERROR!" message.