Pre-Installation Guidelines; Installing The Cisco M Sfs7000E Infiniband Switch - Cisco M SFS7000E Installation Note

Infiniband blade switch for the dell modular server chassis
Table of Contents

Advertisement

Pre-installation Guidelines

Pre-installation Guidelines
This section describes some pre-installation guidelines. Before you begin installation, complete the
following procedures:
If you order the switches with the Dell Modular Server Chassis, the switches are already installed, and
Note
no unpacking is required. The unpacking procedure applies only if you order a
Cisco M SFS7000E InfiniBand Switch, separately or without a chassis.

Installing the Cisco M SFS7000E InfiniBand Switch

This section describes how to install the Cisco M SFS7000E InfiniBand Switch.
The Cisco M SFS7000E InfiniBand Switch can be hot-swapped while the Dell 10G system (PowerEdge)
is online. When you install a switch, you do not need to power down the server chassis.
The Cisco M SFS7000E InfiniBand Switch fits into four different bays on the Dell Modular Server
Chassis. These bays connect to either fabric B or C. Each one of these fabrics connects to a mezzanine
card on each of the 16 server modules. The HCA is designed to reside in these mezzanine connectors.
Two switches may be used for each fabric in a non-blocking configuration. Multiple fabrics may be used
simultaneously for increased bandwidth.
Each bay into which a Cisco M SFS7000E InfiniBand Switch fits must contain either a switch or a blank
Note
input/output module (IOM). When you remove a switch, you must either replace it with an identical
switch or a blank IOM within one minute of removal.
To install the Cisco M SFS7000E InfiniBand Switch in the Dell Modular Server Chassis, perform the
following steps:
Select a chassis I/O module bay in which to install the switch. (See
Step 1
module bays.)
If the HCA IB mezzanine card B is installed, you may install the Cisco M SFS7000E InfiniBand Switch
in I/O slots B1 and/or B2. If the HCA IB mezzanine card C is installed, you may install the
Cisco M SFS7000E InfiniBand Switch in I/O slots C1 and/or C2.
Cisco M SFS7000E Installation Note: InfiniBand Blade Switch for the Dell Modular Server Chassis
6
Ground yourself using an approved ground wrist strap.
Make sure that you have the correct cables.
Unpack the Cisco M SFS7000E InfiniBand Switch. Remove the packaging from around the switch.
Do not cut the packaging, as you could damage the switch. Save the box and packaging.
Figure 3
for the location of the I/O
78-18371-01