Error Messages and Recovery Procedures
Error Message CMP-5-REMOVE The Device is removed from the cluster (Cluster
Name:[chars])
Explanation
name.
Recommended Action

Environment Messages

This section contains the Environment error messages.
Error Message ENVIRONMENT-2-FAN_FAULT
Explanation
Action
if a fan on the switch has failed. The Catalyst 2950 switch can operate normally with one failed fan.
Replace the switch at your convenience.

GigaStack Messages

This section contains the GigaStack error messages.
Error Message GIGASTACK-3-INIT_FAILURE
Explanation
Recommended Action
Error Message GIGASTACK-6-LOOP_BROKEN
Explanation
loss. Link 2 of the Master Loop Breaker is re-enabled to replace the broken line.
Recommended Action
Error Message GIGASTACK-6-LOOP_DETECTED
Explanation
GigaStack GBIC is selected as the Master Loop Breaker. Link 2 of this GigaStack GBIC is disabled
to break the loop.
Recommended Action
Catalyst 2950 Desktop Switch Software Configuration Guide
B-4
The message means that the device is removed from the cluster: [chars] is the cluster
No action is required.
This message means that an internal fan fault is detected.
Either check the switch itself, or use the show env privileged EXEC command to determine
This message means that the Gigastack GBIC failed POST.
Remove the Gigastack GBIC and re-insert it into the GBIC slot.
This message means that a loop formed by GigaStack modules is broken because of link
No action is required.
This message means that a loop has been detected in the GigaStack, and that this
No action is required.
Appendix B
System Messages
78-11380-03