MSC4000 - MSC15000 USER MANUAL

2.3. Installation of Dewpoint Probe

• Dryer will not run if Dewpoint Probe is not connected to the cable from the controller.
• Do NOT run the dryer without the probe installed as shown and described below!
• Install the probe into the evaporator.
• Do NOT bend!
• Install into the evaporator dully inserted past the tubesheet into one of the evaporator tubes.
• Note – When installing the probe, use a thread-lock sealant on the brass and steel threads.
• If probe is not installed correctly it WILL result in damage to the evaporator, consult factory if you are unsure.
CORRECT INSTALLATION OF PROBE
PROBE GOES HERE AND MUST BE FULLY
INSERTED AS SHOWN PAST THE TUBESHEET
INTO AN EVAPORATOR TUBE.
NOT FULLY INSERTING THE PROBE WILL
RESULT IN SERIOUS PRODUCT FAILURE.
WRONG WAY - PROBE NOT FULLY INSTALLED
- WILL RESULT IN FAILURE!
WRONG WAY - DO NOT BEND PROBE TO INSTALL!
6