Fire Hazard; Label Application - Carrier AGAGC9PNS01D Installation Instructions Manual

Gas conversion kit, propane to natural condensing (90%+) furnaces 40,000 btuh to 140,000 btuh models only
Table of Contents

Advertisement

AGAGC9PNS01D Gas Conversion Kit, Propane to Natural: Installation Instructions
Fig. 25 – Modulating Gas Valve Adjustment
WARNING
!

FIRE HAZARD

Failure to follow this warning could result in personal injury, death,
and/or property damage.
Manifold pressure trap set screw must be tightened or 1/8-in. (3 mm)
NPT pipe plug must be installed to prevent gas leaks.
©2022 Carrier. All Rights Reserved.
A Carrier Company
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
13. Turn furnace gas valve switch to ON position.
14. Turn on furnace power supply.
15. Set room thermostat to call for heat.
16. Check pressure tap plug for gas leaks when main burners ignite.
17. Check for correct burner flame.

LABEL APPLICATION

1. Fill in Conversion Responsibility Label 348712-205 and apply to
2. Attach Conversion Rating Plate Label 348712-201, -204, -206,
A11451
3. Attach Gas Control Conversion Label 348712-202 to gas valve. Do
CHECKOUT
1. Observe unit operation through two complete heating cycles.
2. See Sequence of Operation in furnace Installation, Start-Up, and
3. Set room thermostat to desired temperature.
Fig. 26 – Gas Conversion Responsibility Label
Fig. 27 – Gas Control Conversion Label
Edition Date: 05/22
16
Blower Access Door of furnace. Date, name, and address of
organization making this conversion are required, see
-207, -208 or -209 to outer door of furnace, see
Fig.
7.
not use 348712-203, which is similar.
Operating Instructions.
Fig.
26.
Fig.
5,
Fig. 6
or
A221027
A221026
Catalog No:AG-KC019SPN-04
Replaces:AG-KC019SPN-03