Variable-speed, ecm induced-combustion, 2-stage 4-way multipoise, non-condensing gas furnace

Advertisement

PG80VTLA
Variable-Speed, ECM
Induced-Combustion, 2-Stage
4-Way Multipoise, Non-Condensing Gas Furnace
Series A
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
CODES AND STANDARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
DURE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
LOCATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
AIR FOR COMBUSTION AND VENTILATION . . . . . . . . . . . . 6
Table 1 - Minimum Free Area Required for Each Combustion Air
opening of Duct to Outdoors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Table 2 - Minimum Space Volumes for 100% Combustion, Ventila-
tion, and Dilution from Indoors . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
UPFLOW INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
DOWNFLOW INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . 9
Table 3 - Opening Dimensions - In. (mm) . . . . . . . . . . . . . . . . . 10
HORIZONTAL INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . 10
AIR DUCTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
GENERAL REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . 12
SUPPLY AIR CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . 12
RETURN AIR CONNECTIONS. . . . . . . . . . . . . . . . . . . . . . . . . 12
Table 4 - Air Delivery - CFM (With Filter)* . . . . . . . . . . . . . . . 13
GAS PIPING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Table 5 - Maximum Capacity of Pipe . . . . . . . . . . . . . . . . . . . . . 19
ELECTRICAL CONNECTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Table 6 - Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
J-BOX RELOCATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
NOTES FOR FIGURES 28 - FIGURES 35: . . . . . . . . . . . . . . . . . . 24
ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
VENTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
GENERAL VENTING REQUIREMENTS . . . . . . . . . . . . . . . . 25
Table 7 - Combined Appliance Maximum Input Rating
in Thousands of Btuh per Hour . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Table 8 - Minimum Allowable Input Rating of
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
START-UP PROCEDURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Portions of the text and tables are reprinted from NFPA 54/ANSI Z223.1E, with permission of National Fire Protection Association, Quincy, MA
02269 and American Gas Association, Washington DC 20001. This reprinted material is not the complete and official position of the NFPA or ANSI
Installation, Start-up, Operating and
Service and Maintenance Instructions
on the referenced subject, which is represented only by the standard in its entirety.
Table 9 - Altitude Derate Multiplier for U.S.A. . . . . . . . . . . . . . 32
Table 10 - Blower Off Delay Setup Switch . . . . . . . . . . . . . . . . 34
Table 11 - Gas Rate (CU ft./hr). . . . . . . . . . . . . . . . . . . . . . . . . . 34
Table 12 - Orifice Size and Manifold Pressure (In. W.C.) for Gas Input
Rate (Tabulated Data Based on 22,000 Btuh High-Heat/14,500 Btuh
for Low-Heat per Burner, Derated 4 Percent for Each 1000 Ft.(305 M)
Above Sea Level). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
PROCEDURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
GENERAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
CARE AND MAINTENANCE. . . . . . . . . . . . . . . . . . . . . . . . . . 39
Table 13 - Filter Size Information - In. (mm) . . . . . . . . . . . . . . . 40
SEQUENCE OF OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
TROUBLESHOOTING GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
PARTS REPLACEMENT INFORMATION GUIDE . . . . . . . . . . . 49
CASING GROUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
ELECTRICAL GROUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
BLOWER GROUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
GAS CONTROL GROUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
HEAT EXCHANGER GROUP. . . . . . . . . . . . . . . . . . . . . . . . . . 49
INDUCER GROUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Use of the AHRI Certified TM Mark indicates a
manufacturer's participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org.
NOTE: Read the entire instruction manual before starting the
installation.

Advertisement

Table of Contents
loading

Summary of Contents for Carrier A Series

  • Page 1: Table Of Contents

    PG80VTLA Variable-Speed, ECM Induced-Combustion, 2-Stage 4-Way Multipoise, Non-Condensing Gas Furnace Series A Installation, Start-up, Operating and Service and Maintenance Instructions SAFETY CONSIDERATIONS ......3 Table 9 –...
  • Page 2 PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions A190045 ACCESSORY VENT FILTER SHIP WT. TOP AND FURNACE SIZE CONNECTION MEDIA CABINET OUTLET BOTTOM LB (KG) BOTTOM FLUE SIZE CABINET WIDTH WIDTH INLET WIDTH COLLAR SIZE 36045A 14-3/16 (360) 12-9/16 (319) 9-5/16 (237) 12-11/16 (322) 4 (102)
  • Page 3: Safety Considerations

    PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions have kept up with changing residential construction practices. We require these instructions as a minimum for a safe installation. WARNING CAUTION CARBON MONOXIDE POISONING HAZARD CUT HAZARD Failure to follow this warning could result in personal injury and/or death.
  • Page 4: Introduction

    PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions 12. Maintain a 1-in. (25 mm) clearance from combustible materials to WARNING supply air ductwork for a distance of 36 in. (914 mm) horizontally from the furnace. See NFPA 90B or local code for further FIRE HAZARD requirements.
  • Page 5: Electrostatic Discharge (Esd) Precautions Proce

    PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions General Installation furnace. Put all used and new controls into containers before touching ungrounded objects. Current edition of the NFGC and the NFPA 90B. For copies, contact the 7. An ESD service kit (available from commercial sources) may also National Fire Protection Association Inc., Batterymarch Park, Quincy, be used to prevent ESD damage.
  • Page 6: Location

    PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions LOCATION CAUTION GENERAL This multipoise furnace is shipped in packaged configuration. Some FURNACE CORROSION HAZARD assembly and modifications are required when used in any of four Failure to follow this caution may result in furnace damage. applications (as shown in Fig.
  • Page 7 PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions Table 1 – Minimum Free Area Required for Each Combustion Air opening of Duct to Outdoors TWO HORIZONTAL DUCTS SINGLE DUCT OR OPENING TWO OPENINGS OR VERTICAL DUCTS FURNACE (1 SQ. IN./2,000 BTUH) (1,100 SQ. MM/KW) (1 SQ.
  • Page 8 PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions 2. For fan-assisted appliances such as this furnace: than 100 in. (0.06 m ). One opening shall commence within 12 in. (300 mm) of the ceiling and the second opening shall commence within 12 in.
  • Page 9: Installation

    PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions INSTALLATION UPFLOW INSTALLATION Bottom Return Air Inlet These furnaces are shipped with bottom closure panel installed in bottom return-air opening. Remove and discard this panel when bottom return PLENUM OPENING air is used. To remove bottom closure panel, perform the following: 1.
  • Page 10: Horizontal Installation

    PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions Table 3 – Opening Dimensions - In. (mm) FURNACE PLENUM OPENING FLOOR OPENING CASING APPLICATION WIDTH Upflow Applications on Combustible or Noncombustible Flooring (subbase 12-11/16 21-5/8 13-5/16 22-1/4 not required) (322) (549) (338) (565)
  • Page 11: Location Relative To Cooling Equipment

    PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions Not all horizontal furnaces are approved for side return air connections. (Refer to Horizontal Return Air Configurations and Restrictions " (6mm) THREADED ROD (Fig. 20) in the “Upflow and Horizontal Furnaces” section.) 4 REQ.
  • Page 12: Air Ducts

    PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions Refer to the instructions supplied with the external filter rack for DO NOT cut main furnace casing to attach supply side air duct, assembly and installation options. humidifier, or other accessories. All accessories MUST be connected to duct external to furnace casing.
  • Page 13 PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions Table 4 – Air Delivery - CFM (With Filter)* COOLING AND HEATING AIR DELIVERY - CFM (Bottom Return With Filter) (SW1-5 and SW2-2 set to OFF, except as indicated. See Notes 1 and 2.) Unit Size: Clg/CF Switch settings External Static Pressure (ESP)
  • Page 14 PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions Table 4 – Air Delivery - CFM (With Filter)* (Continued) COOLING AND HEATING AIR DELIVERY - CFM (Bottom Return With Filter) (SW1-5 and SW2-2 set to OFF, except as indicated. See Notes 1 and 2.) See Note 4 Low-Cooling 1155...
  • Page 15 PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions Table 4 – Air Delivery - CFM (With Filter)* (Continued) COOLING AND HEATING AIR DELIVERY - CFM (Bottom Return With Filter) (SW1-5 and SW2-2 set to OFF, except as indicated. See Notes 1 and 2.) Unit Size: Clg/CF Switch settings External Static Pressure (ESP)
  • Page 16 PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions Table 4 – Air Delivery - CFM (With Filter)* (Continued) COOLING AND HEATING AIR DELIVERY - CFM (Bottom Return With Filter) (SW1-5 and SW2-2 set to OFF, except as indicated. See Notes 1 and 2.) Cont.
  • Page 17 PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions Table 4 – Air Delivery - CFM (With Filter)* (Continued) COOLING AND HEATING AIR DELIVERY - CFM (Bottom Return With Filter) (SW1-5 and SW2-2 set to OFF, except as indicated. See Notes 1 and 2.) Unit Size: Clg/CF Switch settings External Static Pressure (ESP)
  • Page 18 PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions DOWNFLOW RETURN AIR CONFIGURATIONS AND RESTRICTIONS A02163 Fig. 18 – Downflow Return Air Configurations and Restrictions 135V24--22 A190054 Fig. 19 – Upflow Return Air Configurations and Restrictions A02162 Fig. 20 – Horizontal Return Air Configurations and Restrictions Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
  • Page 19: Gas Piping

    PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions GAS PIPING WARNING Gas piping must be installed in accordance with national and local codes. Refer to current edition of NFGC in the U.S. FIRE OR EXPLOSION HAZARD Installations must be made in accordance with all authorities having A failure to follow this warning could result in personal injury, death, jurisdiction.
  • Page 20: Electrical Connections

    PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions ELECTRICAL CONNECTIONS Install a sediment trap in riser leading to furnace. (See Fig. 23). Connect a capped nipple into lower end of tee. Capped nipple should extend Fig. 24 for field wiring diagram showing typical field 115-v wiring. below level of furnace gas controls.
  • Page 21: J-Box Relocation

    PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions Table 6 – Electrical Data OPERATING VOLTAGE MAX WIRE MAX. FUSE VOLTS - UNIT MAX. UNIT MIN. WIRE LENGTH OR CKT. BKR FURNACE SIZE HERTZ - RANGE † AMPS GAUGE AMPACITY ‡...
  • Page 22 PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions Electrical Connection to J-Box 3. Secure power cord to J-Box bracket with a strain relief bushing or a connector approved for the type of cord used. Electrical Box on Furnace Casing Side 4.
  • Page 23 PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions See notes 1, 2, 3, 4, 6, 8, 9, 10, 12, 13 and 15 on the page following these figures A03178 Fig. 31 – Two-Stage Furnace with Two-Speed Heat Pump See notes 2, 5, 8, 10, 11 and 12 (Dual Fuel) on the page following these figures A03179...
  • Page 24: Notes For Figures 28 - Figures 35

    PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions See notes 1 and 2 on the page following these figures See notes 1, 2, 3, 4, 12, 13, 14, 15, and 17 A03184 Fig. 35 – Single-Stage Thermostat with Two-Stage Furnace and on the page following these figures A03182 Two-Speed Air Conditioner...
  • Page 25: Accessories

    PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions ACCESSORIES (if used) to the 1/4-in male quick-connect HUM terminal and COM-24V screw terminal on the control board thermostat strip. 1. Electronic Air Cleaner (EAC) The HUM terminal is energized when blower is energized in Connect an accessory Electronic Air Cleaner (if used) using 1/4-in heating.
  • Page 26 PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions vent connector capacity is equal to or lower than the low fire rate of the furnace and the FAN-Max vent connector capacity is equal to or CHIMNEY INSPECTION CHART higher than the furnace high fire rate. For additional requirements refer to the National Fuel Gas Code NFPA 54/ANSI Z223.1 and ANSI/NFPA 211 Chimneys, Fireplaces, Vents, and Solid Fuel Burning Appliances 3.
  • Page 27: In Thousands Of Btuh Per Hour

    PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions 3. The combined appliance input rating is less than the maximum Table 8 – Minimum Allowable Input Rating of capacity given in Table 7, and Space-Heating Appliance in Thousands of Btuh per Hour 4.
  • Page 28 PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions CAUTION CAUTION BURN HAZARD CUT HAZARD Failure to follow this caution may result in personal injury. Failure to follow this caution may result in personal injury. Hot vent pipe is within reach of small children when installed in Sheet metal parts may have sharp edges or burrs.
  • Page 29 PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions SEE NOTES: 1,2,4,7,8,9 SEE NOTES:1,2,3,4,5,7,8,9 on the page following on the page following these figures these figures A03208 A03210 Fig. 38 – Upflow Application - Vent Elbow Up Fig. 41 – Downflow Application - Vent Elbow Up then Left SEE NOTES: 1,2,4,5,7,8,9 SEE NOTES: 1,2,3,4,7,8,9 on the pages following...
  • Page 30 PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions SEE NOTES: 1,2,4,5,7,8,9 on the page following these figures SEE NOTES: 1,2,4,5,6,7,8,9 on the page following these figures A03207 A03215 Fig. 44 – Downflow Application - Vent Elbow Left then Up Fig.
  • Page 31: Start-Up, Adjustment, And Safety Check

    PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions START-UP, ADJUSTMENT, AND SAFETY CHECK GENERAL 1. Maintain 115-v wiring and ground. Improper polarity will result in rapid flashing LED and no furnace operation. 2. Make thermostat wire connections at the 24-v terminal block on the furnace control.
  • Page 32: Adjustments

    PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions will not operate if any thermostat signal is present at the control. (Refer For installations below 2000 Ft. (610 M), refer to the unit rating to service label attached to furnace or see Fig.
  • Page 33 PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions (out) to decrease input rate or clockwise (in) to increase input CAUTION rate. NOTE: DO NOT set low-heat manifold pressure less than 1.4-In. W.C. UNIT DAMAGE HAZARD or more than 1.7-In. W.C. for natural gas. If manifold pressure is outside this range, change main burner orifices.
  • Page 34 PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions SW2-7 and SW2-8 either ON or OFF. Select the required airflow. CAUTION (See Fig. 55). NOTE: 5.5 ton airflow will truncate at 2200 cfm on applicable models. FURNACE OVERHEATING HAZARD For a complete explanation of cooling airflow, refer to the section titled “Sequence of Operation.”...
  • Page 35: Above Sea Level)

    PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions Table 12 – Orifice Size and Manifold Pressure (In. W.C.) for Gas Input Rate (Tabulated Data Based on 22,000 Btuh High-Heat/14,500 Btuh for Low-Heat per Burner, Derated 4 Percent for Each 1000 Ft.(305 M) Above Sea Level) SPECIFIC GRAVITY OF NATURAL GAS 0.58 0.60...
  • Page 36 PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions Table 12 – Orifice Size and Manifold Pressure (In. W.C.) for Gas Input Rate (Tabulated Data Based on 22,000 Btuh High-Heat/14,500 Btuh for Low-Heat per Burner, Derated 4 Percent for Each 1000 Ft.(305 M) Above Sea Level) (Continued) SPECIFIC GRAVITY OF NATURAL GAS AVG.
  • Page 37 PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions A190047 Fig. 53 – Service Label A190048 Fig. 54 – Furnace Setup Switch Description 1. Default A/C airflow when A/C setup switches are in OFF position. 2. Default Low-Stage A/C airflow when CF switches are in OFF position A190049 Fig.
  • Page 38: Service And Maintenance

    PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions SERVICE AND MAINTENANCE Electrical Controls and Wiring PROCEDURES WARNING Untrained personnel can perform basic maintenance functions such as cleaning and replacing air filters. All other operations must be performed ELECTRICAL SHOCK HAZARD by trained service personnel.
  • Page 39: Care And Maintenance

    PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions CARE AND MAINTENANCE 7. Release blower access door switch, install blower access door and replace outer door or refer to the SERVICE label on the front of the WARNING blower access door for more information. Component Self-Test FIRE OR EXPLOSION HAZARD Component Test can ONLY be initiated by performing the following:...
  • Page 40 PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions 5. If equipped with factory-specified disposable media filter, replace 9. If a greasy residue is present on blower wheel, remove wheel from only with media filter having the same part number and size. For the blower housing and wash it with an appropriate degreaser.
  • Page 41 PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions Cleaning Heat Exchanger 9/32” The following steps should be performed by a qualified service agency. 7.1mm NOTE: If the heat exchangers get a heavy accumulation of soot and carbon, they should be replaced rather than trying to clean them 5/16”...
  • Page 42: Sequence Of Operation

    PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions (9.) Reinstall burner assembly. Center burners in cell openings. transformer TRAN, inducer motor IDM, blower motor BLWM, hot-surface igniter HSI, and gas valve GV. 10. Remove old sealant from cell panel and collector box flange. 1.
  • Page 43 PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions d. Flame-Proving - When the burner flame is proved at the to high. The high-heat pressure switch relay HPSR is flame-proving sensor electrode FSE, the inducer motor IDM de-energized to close the NC contact. When sufficient pressure is switches to low-speed unless the furnace is operating in available the high-heat pressure switch HPS closes, and the high-heat gas valve solenoid GV-HI is energized.
  • Page 44 PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions circuits switch the outdoor unit to high-cooling speed, and the motor BLWM will operate at continuous blower airflow. R-to-G-and-Y1-and-Y/Y2 circuits transition the furnace blower motor Continuous blower airflow selection is initially based on the CF BLWM to high-cooling airflow.
  • Page 45 PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions delay, the blower motor BLWM will shut OFF unless G is still energized, in which case the blower motor BLWM will operate at continuous blower airflow. 7. Component test The furnace features a component test system to help diagnose a system problem in the case of a component failure.
  • Page 46: Wiring Diagram

    PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions WIRING DIAGRAM Fig. 59 shows a schematic for furnace wiring information. A190269 Fig. 59 – Wiring Diagram Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
  • Page 47: Troubleshooting Guide

    PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions TROUBLESHOOTING GUIDE A14311a Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
  • Page 48 PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions A14311b Fig. 60 – Troubleshooting Guide Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
  • Page 49: Parts Replacement Information Guide

    PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions PARTS REPLACEMENT INFORMATION GUIDE Hot surface igniter CASING GROUP Gas valve Manual reset limit switches Outer door Burner support assembly Blower door Top filler plate HEAT EXCHANGER GROUP Bottom filler plate Heat exchanger cell Bottom enclosure Cell panel...
  • Page 50 PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions © 2020 Carrier. All rights reserved. Edition Date: 05/20 Catalog No:IMG-PG80VTLA-02 A Carrier Company Replaces:IM-PG80VTLA-02 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

This manual is also suitable for:

Pg80vtla

Table of Contents