Technical Data; Operation; Dmx Control - Varytec LED PAD 147 User Manual

Table of Contents

Advertisement

Important:
Damages caused by the disregard of this user manual are not subject to
warranty. The dealer will not accept liability for any resulting defects or
problems. Make sure the electrical connection is carried out by qualified
personnel. All electrical and mechanical connections have to be carried out
according to the European safety standards.

2. Technical Data

Power supply
Power consumption
Current
Sound to Light
DMX512 connection
Weight
Measurements
Maximum ambient temperature
Maximum housing temperature
Fuse
Channel
Number of LEDs
Beam angle

3. Operation

3.1. DMX Control

To set up your desired DMX address, you have to set up the dipswitch on the backside as follows:
-
Set the dip 10 to OFF
-
With all the other dipswitches 1 to 9 you can set up the DMX address regarding the binary
system. In this system each dip has a value, which you have to add to get the dmx address.
Dip
1
2
Wert
1
2
If you want to set the address 10 then you have to setthe dips 4 and 2 to ON, because theire
values are 2 and 8 and 2+8=10.
Remember that the item needs 6 channels.
So if you want to set the first item to address 1, the second item has to be minimum address 7,
because 1+6=7.
100 - 240V 50/60Hz
15W
0.1A
Via built in mic
3 Pin XLR
2,1 Kg
273 x 265 x 79mm
-20° - +40°C
+20° - +60°C
F1A, 250V
6
147 x 10mm LEDs (51R, 48G, 48B)
25°
3
4
5
4
8
16
4 / 8
6
7
8
32
64
128
9
256

Advertisement