Troubleshooting

Problem
The eduction rate is low.
There is no rinsing or flushing action.
There are leaks at the fittings.
Possible Cause
1. There is a lack of flow and pressure to
the eductor system.
2. The outlet/Inlet hose is obstructed.
3. Fittings with elbows or other
flow-restrictions are in the eductor
outlet.
1. The bottle rinse nozzle is plugged or
clogged.
2. The flush tee is plugged or clogged.
1. The fittings are damaged.
2. The thread sealant is worn.
17
Corrective Action
1. Increase the pump speed. Turn the
agitation throttling toward the closed
position.
2. Disassemble and remove any
obstructions.
3. Use only sweeping turns with flexible
hoses.
1. Disassemble the rotary portion of the
nozzle from the lower valve assembly
and back flush until the nozzle ports
are clear of debris.
2. Disassemble the flush tee and clean
until the nozzle ports are clear of
debris.
1. Check for cracks in the fitting. Replace
the fitting if necessary.
2. Disassemble and seal the joint with
joint seal compound if a leak occurs on
the threads.