EXCELL PRECISION CO., LTD.
hold 0
= No hold function
hold 1
= For varying weighing value, the scale will automatically hold the maximum weighing value to
display. To exit hold mode, press any key (except the
hold 2
= After the scale is stabilized, the scale will automatically hold the display value( not changeable
due to external variables)To exit hold mode, press any key.( except the
hold 3
= After the scale is stabilized, the scale will automatically hold the display value( not changeable
due to external variables).After zero return ( or weight is less than 10d), the scale exits the
hold mode automatically.
hold 4
= Animal Scale function. When animal is on the scale platter and is stable, the scale will
automatically hold the display value (not changeable due to external variables). After the
animal is off the scale platter, the scale exits the hold mode automatically.
Animal Scale Hold Setup (hold 4)
Select hold 4
Press
Press
Press
Press

3-6 F11 ID Code Setting

(must be used with r n P 1, r n P 2, r n P 8 of F5)
Press
key or
Press
key
Press
key
0201810X
key
key
%
key
key
key to select F11
Machine ID code setting:
Use
(1) "00": RS-232 does not transmit Machine ID.
(2) "01~99": RS-232 transmits Machine ID.
key).
Error Allowance Range setup:
Use
and
from 1%~100%.Default is 10%.
Numbers of count to average:
Use
and
16, 32, 64. Default is 8.
and
to set 01 ~ 99. Default setting: 00
20
key )
to enter value ranged
to select one of 1, 2, 4, 8,