Sony HCD-M10 Service Manual page 23

Micro hi-fi component system
Table of Contents

Advertisement

4. CD Ship Mode (Setting the Position for Transportation)
1.
Press ?/1 button to turn the power on.
2.
Press FUNCTION to change the function to "CD".
3.
Press three buttons x , ENTER/START and CD u simultaneously.
4.
The CD mechanism goes to the transportation mode.
5.
When "LOCK" is displayed, disconnect the power cord.
6.
The lock is released when the power turns on next.
5. Ship Mode (Setting the Position for Transportation)
This mode is the combination of CD SHIP mode and Cold reset.
In this mode, the MD reset is not activated.
Press ?/1 button to turn the power on.
1.
Press three buttons x , ENTER/START and MD u simultaneously.
2.
3.
When "LOCK" is displayed, disconnect the power cord.
4.
The lock is released when the power turns on next.
MD TEST MODE
1. PRECAUTIONS FOR USE OF TEST MODE
• As operations related to loading will be performed regardless of the test mode operations being performed, be sure to check that the disc
is stopped before setting and removing it.
Even if the Z MD button is pressed while the disc is rotating during continuous playback, continuous recording, etc., the disc will not
stop rotating.
Therefore, it will be ejected while rotating.
Be sure to press the Z MD button after pressing the MENU/NO "R" button and the rotation of disc is stopped.
1-1. Recording laser emission mode and operating buttons
• Continuous recording mode (CREC 1MODE) (C35)
• Laser power check mode (LDPWR CHECK) (C13)
• Laser power adjustment mode (LDPWR ADJUST) (C04)
• Comparison with initial Iop value written in nonvolatile memory (Iop Compare) (C27)
• Write current Iop value in read nonvolatile memory using microprocessor (Iop NV Save) (C06)
• Traverse (MO) check (EF MO CHECK) (C14)
• Traverse (MO) adjustment (EF MO ADJUST) (C07)
• When pressing the z MD button.
2. SETTING THE TEST MODE
Procedure : 1. Press the
?
/
1
2. Press three buttons of
When the test mode is set, "[Check]" will be displayed. Pressing the
three groups; ···Tt [Check] Tt [Service] Tt [Develop] Tt ···.
Note: Do not use the test mode in the [Develop] group.
If used, the unit may not operate normally.
If the [Develop] group is set accidentally, press the MENU/NO "R" button immediately to exit the [Develop] group.
3. RELEASING THE TEST MODE
utton twice and ?
Press the REPEAT
b
4. BASIC OPERATIONS OF THE TEST MODE
All operations are performed using the
The functions of these buttons are as follows.
Function name
"R"
"R"
.
, >
buttons
ENTER/YES "R"
button
MENU/NO "R"
button
REC MODE
button
button to turn the power on.
, REC MODE , and FUNCTION simultaneously.
x
1 button to turn the power off, the set goes to the standby mode.
/
.
"R" ,
>
"R" , ENTER/YES "R" , MENU/NO "R" and REC MODE buttons.
Function
Changes parameters and modes
Proceeds onto the next step. Finalizes input
Returns to previous step. Stops operations
Selects the sub menu
"R" or
"R" button between the following
.
>
HCD-M10
23

Advertisement

Table of Contents
loading