- Vertical Airflow Direction:-
In "Manual" or "Auto" setting, the vane will automatically change
to Auto Air Swing. /
- Economy Mode will stop if:-
- Economy Mode button is pressed again.
- Stopped by ON / OFF switch.
- Timer OFF activates.
- Powerful mode button is pressed.
- Auto or Manual air swing button is pressed.
- Fan Speed control button is pressed.
- Sleep Mode button is pressed ON.
- Operation Mode is changed.
8.8. Random Auto Restart Control
- If there is a power failure, operation will be automatically restarted
after 3 to 5 1/2 minutes when the power is resumed.
It will start with previous operation mode and airflow direction. /
- Restart time is decided randomly using 4 parameter:-
Intake air temperature, setting temperature, fan speed and Air
Swing Blade position. /
- Auto Restart Control is not available when Timer or Sleep Mode is
set. /
- This control can be omitted by open the circuit of JX2. (Refer
Circuit Diagram) /
8.9. Indoor Fan Speed Control
- Auto Fan Speed Control
When set to Auto Fan Speed, the fan speed is adjusted between
maximum and minimum setting as shown in the table. /
- Manual Fan Speed Control
Basic fan speed adjustment (3 settings, from Lo to Hi) can be
carried out by using the Fan Speed selection button at the remote
control. /