Rinnai REU-VEP2730FFD-US Installation And Operation Manual page 49

Tankless water heater (with pump)
Table of Contents

Advertisement

No Flame
12
Check that the gas is turned on at the
water heater, meter, or cylinder.
Check for obstructions in the flue outlet.
If the system is propane, make sure
that gas is in the tank.
Ensure gas line, meter, and/or regulator
is sized properly.
Ensure gas type and pressure is
correct.
Bleed all air from gas lines.
Ensure proper venting material was
installed.
Ensure condensation collar was
installed properly.
Ensure vent length is within limits.
Verify parameter setting are set
properly.
Check power supply for loose
connections.
Check power supply for proper voltage
and voltage drops.
Ensure flame rod wire is connected.
Check flame rod for carbon build-up.
Disconnect and reconnect all wiring
harnesses on unit and PC board.
Check for DC shorts at components.
Check gas solenoid valves for open
circuits.
Remove burner plate; inspect burner
surface for condensation/debris.
* See "Electrical Diagnostics" on Technical Data
Sheet located on inside front cover of water heater.
Rinnai Tankless Water Heater Installation and Operation Manual
Thermal Fuse
14
Check for restrictions in air flow around
unit and vent terminal.
Check gas type of unit and ensure it
matches gas type being used.
Check for low water flow in a circulating
system causing short-cycling.
Check for foreign materials in
combustion chamber and exhaust
piping.
Check heat exchanger for cracks or
separations.
Check heat exchanger surface for hot
spots which may be caused by scale
build-up. Refer to instructions in manual
for flushing heat exchanger. Hard water
must be treated to prevent scale build
up or damage to the heat exchanger.
Measure resistance of safety circuit.
Ensure high fire and low fire manifold
pressure is correct.
Check for improper gas conversion of
product.
High Outgoing Temperature
16
Check for restrictions in air flow around
unit and vent terminal.
Check for low water flow in a circulating
system causing short-cycling.
Check for foreign materials in
combustion chamber and exhaust
piping.
Check for blockage in the heat
exchanger.
Check the thermistor sensor and clean
sensor of scale build-up.
Electrical Grounding
19
Check all components for electrical
short.
Outgoing Water Temperature Thermistor
32
Check sensor wiring for damage.
Measure the resistance of the sensor.
(See Electrical Diagnostics)
Clean sensor of scale build-up.
Replace sensor if necessary.
Heat Exchanger Thermistor
33
Check sensor wiring for damage.
Measure resistance of sensor. (See
Electrical Diagnostics)
Replace sensor if necessary.
49