4.3.7 Installation Location Checklist
Use this checklist to ensure you have selected the correct location for the water heater.
The water heater is not exposed to corrosive compounds in the air.
The water heater location complies with the required clearances.
For indoor models, the planned venting will not exceed the maximum length for the number of
elbows used.
The planned venting termination/air intake location meets the clearances.
Indoor air is not being used for combustion.
The water supply does not contain chemicals or exceed total hardness that will damage the
heat exchanger.
A standard 3 prong 120 V AC, 60 Hz properly grounded wall outlet for indoor models or other
120 V AC, 60 Hz source is available.
The installation must conform with local codes or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation
Code, CSA B149.1. If installed in a manufactured home, the installation must conform with the
Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 and/or CAN/
SCA Z240 MH Series, Mobile Homes.
Leave the entire manual taped to the water heater or give the entire manual directly to the
consumer.
Rinnai Tankless Water Heater Installation and Operation Manual