Step 6 Connect Batteries - Chamberlain INSL24UL Installation Manual

Ndustrial dc vehicular slide gate operator
Hide thumbs Also See for INSL24UL:
Table of Contents

Advertisement

Step 6 Connect Batteries

7AH Batteries
The batteries are charged in the circuit by the integrated transformer.
1. Turn the AC power switch to OFF.
2. Turn the battery switch OFF .
3. Connect a jumper between the positive(+) terminal of the battery to
the negative terminal(-) of the other battery.
4. Connect the red battery wire from the operator to the positive(+)
terminal of the battery.
5. Connect the black battery wire from the operator to the negative (-)
terminal of the battery.
6. Turn the battery switch ON .
7. Turn the AC power switch to ON to restore AC power.
33AH Batteries
The batteries are charged in the circuit by the integrated transformer.
The 33AH application requires battery harness K41-0102-000, see
Accessories.
1. Turn the AC power switch to OFF.
2. Turn the battery switch OFF.
3. Connect a jumper between the positive(+) terminal of the battery to
the negative terminal(-) of the other battery.
4. Connect the (+) terminal of the battery to the red battery wire from
the operator using the RED harness kit wire .
5. Connect the (-) terminal of the battery to the black battery wire from
the operator using the BLACK harness kit wire.
6. Turn the battery switch ON .
7. Turn the AC power switch to ON to restore AC power.
INSTALLATION
Red Wire
Red Wire
Red wire from
battery harness
33AH, HD Gates
K41-0102-000
17
Jumper
Black Wire
Battery Wiring
Jumper (White Wire)
from K41-0102-000
Battery Wiring
Black Wire
Black wire
from battery
harness 33AH,
HD Gates
K41-0102-000