Code
Meaning
61
CLOSE EYE/INTERRUPT held
62
CLOSE EDGE held
63
OPEN EYE/EDGE held
64
CLOSE EYE/INTERRUPT held
65
CLOSE EYE/EDGE held
66
OPEN EYE/EDGE held
67
Wireless edge triggered extended time
68
Wireless edge loss of monitoring
69
Wireless edge triggered
CLOSE EYE/INTERRUPT triggered, causing
70
reversal, preventing close, or resetting TTC
CLOSE EDGE triggered, causing reversal,
71
preventing close, or canceling TTC
OPEN EYE/EDGE triggered, causing reversal or
72
preventing opening
CLOSE EYE/INTERRUPT triggered, causing
73
reversal, preventing close, or resetting TTC
CLOSE EYE/EDGE triggered, causing reversal and
74
preventing close or canceling TTC
OPEN EYE/EDGE triggered, causing reversal or
75
preventing opening
Close input (EYE/EDGE) communication fault from
80
other operator
Open input (EYE/EDGE) communication fault from
81
other operator
Close input (EYE/EDGE) communication fault
82
(expansion board)
Open input (EYE/EDGE) communication fault
83
(expansion board)
Non-monitored device detected on the wireless
84
safety system
90
Low Voltage Input to Motor Drive Fault
91
Force reversal
93
RPM / STALL reversal
95
Motor start failure
96
Motor Drive Board Fault
99
Normal operation
APPENDIX
Solution
Check wired input on control board; check for alignment or obstruction;
squeeze and release the edge and verify main board edge LED changes;
check for eye alignment or obstruction.
Check wired input on expansion board; check for alignment or
obstruction; squeeze and release the edge and verify main board edge
LED changes; check for eye alignment or obstruction.
Check wired input for wiring issue or obstruction; squeeze and release
the edge and verify main board edge LED changes
Check wireless edge inputs.
IF an obstruction occurred, no action required. If an obstruction did NOT
occur, check inputs and wiring.
IF an obstruction occurred, no action required. If an obstruction did NOT
occur, check alignment, inputs, and wiring on control board
IF an obstruction occurred, no action required. If an obstruction did NOT
occur, check alignment, inputs, and wiring on expansion board.
Check inputs and communication method between operators, either
wired bus or radio. Ensure operator is powered. May have to erase the
wireless communication and reprogram the two operators.
Check the connections between the control board and the expansion
board.
Non-monitored contact closure devices are not supported. Make sure
connected devices are monitored. Check edges for proper orientation and
resistive end cap connection.
Verify incoming power meets voltage requirement of operator. Verify
battery voltage is above 20V. Disconnect all power, wait 15 seconds,then
reconnect power (reboot). If issue persists, replace power supply.
Check for obstruction. If no obstruction, check that the mechanical
assembly is engaged and free to move. See Adjust the Limits, Speed, and
Force
page
21.
Check for obstruction. If no obstruction, check the operator wiring and
that the mechanical assembly is engaged and free to move. Replace APE
assembly.
Operator attempted to run, no response from motor drive assembly.
Check connector and harness. Check for other error codes and resolve
those first. If connected properly and still not working,test motor and/or
motor drive.
Check connections to motor drive board. Power cycle and retry. Replace
motor drive board if issue persists.
No action required