Gate Operator Setup Examples

The following are example setups for the gate operator. Your specific site requirements may be different. Always setup the operator system to the site
requirements, including all necessary entrapment protection devices.
COMMERCIAL/GENERAL ACCESS: A residential community (more than four homes) having one or more gated entrances/exits, allowing vehicle access
trumps security concerns
COMMERCIAL: Business site where security (gate closed) is important
INDUSTRIAL: Large business site where security is required
COMMERCIAL/GENERAL ACCESS
SETTING
Quick Close switch setting
Normally set to OFF. Normal gate close
(timer or control).
AC Fail Open switch setting Normally set to BATT. For local jurisdiction
requirement, set to OPEN so that the gate will
open approximately 15 seconds after AC
power fail.
Low Battery switch setting
Normally set to OPEN. If powered from
battery and battery is low, gate automatically
opens and stays open.
Anti-Tail switch setting
Normally set to OFF. CLOSE EYES/Interrupt
loop reverses a closing gate.
Bipart Delay switch setting
For DUAL-GATE site, set to ON for gate that
delays upon opening.
Use with SAMS (Sequence Access
Aux Relay Out – Open Limit
Switch
Management System).
Aux Relay Out – Close Limit
Typically not required.
Switch
Aux Relay Out – Gate
Attach alert signal (audible or visual alert
Motion
system).
Aux Relay Out – Pre-Motion
Attach alert signal (audible or visual alert
Delay
system).
Aux Relay Out – Power
Attach visual alert to know when system is
charging batteries (i.e. not running on
batteries).
Attach alert signal (audible or visual alert
Aux Relay Out – Tamper
system) to indicate if gate is manually
(Slide Gates Only)
tampered with by being pushed off of close
limit.
Cycle Quantity Feedback
Use during servicing only to determine
operator cycles.
Fire Dept Open Input
Connect emergency access system (Knox box
switch, SOS system, etc.).

OPERATION

COMMERCIAL
Normally set to OFF. Normal gate close
(timer or control).
Normally set to BATT. Run on battery if AC
power fails.
Normally set to CLOSE. If powered from
battery and battery is low, gate stays closed.
Set to ON. In attempt to prevent vehicle tail-
gating, CLOSE EYES/ Interrupt loop pauses a
closing gate.
For DUAL-GATE site, set to ON for gate that
delays upon opening.
1. Use with SAMS (Sequence Access
Management System).
2. Connect "Gate Open" indicator (e.g.
light).
Connect "Gate Close/Secure" indicator (e.g.
light).
Attach alert signal (audible or visual alert
system).
Attach alert signal (audible or visual alert
system).
Attach visual alert to know when system is
charging batteries (i.e. not running on
batteries).
Attach alert signal (audible or visual alert
system) to indicate if gate is manually
tampered with by being pushed off of close
limit.
Use during servicing only to determine
operator cycles.
Typically not required.
27
INDUSTRIAL
Set to ON, so that gate closes immediately
after vehicle passes CLOSE EYES/Interrupt
loop.
Normally set to BATT. Run on battery if AC
power fails.
Normally set to CLOSE. If powered from
battery and battery is low, gate stays closed.
Set to ON. In attempt to prevent vehicle tail-
gating, CLOSE EYES/ Interrupt loop pauses a
closing gate.
For DUAL-GATE site, set to ON for gate that
delays upon opening.
1. Use with SAMS (Sequence Access
Management System).
2. Connect "Gate Open" indicator (e.g.
light).
Connect "Gate Close/Secure" indicator (e.g.
light).
Attach alert signal (audible or visual alert
system).
Attach alert signal (audible or visual alert
system).
Attach visual alert to know when system is
charging batteries (i.e. not running on
batteries).
Attach alert signal (audible or visual alert
system) to indicate if gate is manually
tampered with by being pushed off of close
limit.
Use during servicing only to determine
operator cycles.
Typically not required.