the following operation.
1. During remote control setting is less than 28 deg
Indoor Fan Speed
Above Hi
Above Me-
Less than Me-
Auto
2. During Powerful ON
However, when less than thermo OFF for 120 sec. continuously,
the above control will be cancel.
- During heating operation, operate the followings control.
1. During Remote Control setting is less than 18 deg
Indoor Fan Speed
Above Hi
Above Lo
Less than Lo
2. During Powerful ON
However, when less than thermo OFF for 100 sec. continuously,
the above control will be cancel.
8.2.2. Protection Control For Cooling & Soft Dry Operation
8.2.2.1. Outdoor Air Temperature Control
The compressor operating frequency is regulated in accordance to the outdoor air temperature
as shown in the diagram below.
minHz =
minHz =
minHz =
minHz =
minHz =
minHz =
minHz =
minHz =
minHz =
21
21
18
16
22
30
25
15
35