Mode:
Cooling
Soft Dry
Heating
Table (d): Quiet (Lo) Mode Shifting
Mode:
Cooling, Soft Dry
Table (e): Fan Speed Shifting
Mode:
Cooling
Soft Dry
Heating
Table (f): Start-Up Shifting
Mode within 60 Minutes from Start-up:
Cooling/Soft Dry
Heating
8.1.2. Compressor Operation Frequency
Period, X (min):
X
20
X
20
X
20
X
20
X
20
X
20
Period, X (min):
20 min
X
50 min
50 min
X
110 min
110 min
X
440 min
Fan Speed:
Lo
Me-, Me, Me+, Auto
Hi
All
Lo
Me-, Me, Me+, Auto
Hi
Temperature Shift (°C)
-2.0
0.0
-1.0
0.0
+3.5
+3.25
Temperature Shift (°C)
-3.0
-4.0
-5.0
Temperature Shift (°C)
-0.25
0.00
+0.25
+0.25
+1.50
+0.75
+0.75
Temperature Shift (°C)
-1.0
+2.0

Hide quick links: