Remote Control Setting Temperature (°C)
16 ~ 18
19 ~ 22
23 ~ 26
27 ~ 30
There is a temperature shifting on T1, T2, and T3 if the operation mode judged is changed from
Cooling/Soft Dry to Heating or vice verse.
Operation Mode change from
Cooling/Soft Dry
Heating
The operation mode chart for this example is as shown in below figure and the operation mode
to be performed will depend on indoor intake air temperature and outdoor air temperature at the
time when the judgment is made.
8.1.7. Indoor Fan Motor Operation
A. Basic Rotation Speed (rpm)
- Required rotation speed for fan is set to respond to the remote
control setting (10 rpm unit)
[Cooling, Dry, Fan]
Remote Control
Tab (rpm)
SHI
E18CK
1530
E21CK
1610
[Heating]
Heating
Cooling/Soft Dry
O
O
Hi
Me+
1440
1360
1520
1420
T1
+10
+8
+7
+6
Temperature shifts (°C)
O
O
Me
Me-
1290
1220
1150
1330
1240
1150
T2
T3
+8
-5
+7
-7
+6
-7
+5
-8
-2
+2
O
Lo
Lo-
SLo
850
760
890
800
SSLo
630
630